Ethernet/Ip Network Connections; Socket Interface - Allen-Bradley Compact GuardLogix 5370 User Manual

Hide thumbs Also See for Compact GuardLogix 5370:
Table of Contents

Advertisement

Connections
Cat. No.
Controller TCP
1769-L30ERMS
256
1769-L33ERMS
1769-L33ERMSK
1769-L33ERMOS
1769-L36ERMS
1769-L36ERMOS
(1)
1769-L37ERMS
(1)
1769-L37ERMOS
(1)
1769-L38ERMS
(1)
1769-L38ERMOS
(1) Available at firmware revision 31.
(2) Total packet rate capacity = I/O Produced Tag, max + HMI/MSG, max Packet rates vary depending on packet size. For more detailed specifications, see the capacity section of the EDS file for the
catalog number.
(3) These are the maximum numbers of CIP I/O connections.

EtherNet/IP Network Connections

Compact GuardLogix 5370 controllers use connections to manage
communication on the EtherNet/IP network. A connection is a point-to-point
communication mechanism that is used to transfer data between a transmitter
and a receiver. Connections can be logical or physical.
You indirectly determine the number of connections the controller uses by
configuring the controller to communicate with other devices in the system.
Connections are allocations of resources that provide more consistent
communication between devices than unconnected messages.
All EtherNet/IP connections are unscheduled. An unscheduled connection is a
message transfer between controllers that the requested packet interval (RPI)
or the program, such as a MSG instruction, triggers. Unscheduled messaging
lets you send and receive data when needed.
Table 8 - Compact GuardLogix 5370 Controller EtherNet/IP Network Port Specifications
CIP
Unconnected
Messages
(backplane +
CIP
Ethernet)
120
256
256
6000 @ 500
bytes/packet

Socket Interface

The Compact GuardLogix 5370 controller can use socket interfaces to
communicate with Ethernet devices that do not support the EtherNet/IP
application protocol.
Examples of devices that do not support the EtherNet/IP application protocol
but can be used in a Compact GuardLogix 5370 controller application include
the following:
• Modbus TCP/IP device
Rockwell Automation Publication 1769-UM022C-EN-P - June 2018
Packet Rate Capacity
(2)
(packets/second)
SNMP
Support
(password
I/O
HMI/MSG
required)
400 messages/
Yes
second @ 20%
comm. timeslice
Communicate Over Networks
Produced/Consumed Tags
Media
Number of Multicast
(3)
Support
Tags, max
Twisted
• 32 multicast
pair
produced tags
• 128 unicast
produced tags
Chapter 5
Unicast
Available
Yes
77