Troubleshooting

This section describes some possible problems that you may experience and provides some
suggestions for easy troubleshooting:
Symptom
Potential cause
No light from
Power supply issue such
fixture.
as faulty connector or
damaged cable.
Fixture does not
Incorrect DMX setup.
respond correctly
to DMX control.
Fault in the DMX network
due to connector or cable
damage or potential
interference from proximity
to a high voltage
installation.
Internal fault.
Condensation
Humidity inside fixture.
visible on inside of
front glass.
52
Exterior Projection 500 User Manual
Remedies
Ensure that the mains supply is connected
and supplying power to the fixture. Check all
power connections and cables.
Ensure that fixture's DMX address matches
address set on DMX control device.
Check that fixture's status LED shows that it is
receiving DMX. If not, check all DMX cables
and connections.
Ensure that DMX link is terminated.
Check that all components on DMX link use
standard DMX polarity.
Attempt to control the fixture with another
DMX control device.
Move or shield the DMX link if it is close to an
unshielded high-voltage installation.
Contact your Martin authorized distributor or
Martin Global Service for assistance.
Condensation inside the fixture is normal in
some atmospheric conditions. The fixture will
gradually expel humidity via its Gore-Tex
pressure relief valve as it cycles on and off.
If required, you can remove excessive
humidity by following the directions given in
'Removing and reinstalling the top cover'
starting on page 32.