Redline AN-30 System User Manual page 51

Table of Contents

Advertisement

If the idle code command is not specified, the default value 0xFF is used.
key, no params.
This is used only with a get operation: tdm get key
This command will get the option key (permitted line types, number of lines, user
data) on the T1/E1 module.
Bit7..5
1
Enable
unused
User
Port
line, params: LINE_TYPE
This command will set the line type on the T1/E1 module (if permitted by the option
key).
LINE_TYPE
0
1
softver, no params
This command is used only with a get operation. Represents the coded software
version.
fanstate, no params
This command will return 1 if the fan is ON (working) and return 0 if the fan is OFF
(not working).
Show Operations
The show operation is:
• tdm showgen
tdm showgen, params: CONFIG
This command is used to get the general configuration parameters from running or
startup config.
The default configuration selected is running config.
CFG
0
1
Redline Communications
KEY fields
Bit4
Bit3
-
1- Enable
1 -Enable
T1 line
E1 line
type
type
Definition
T1 line
E1 line
Definition
running config
startup config
Page 51 of 80
AN-30 System User Manual
Bit2
Bit1..0
00-1 line
01-2 lines
10-4 lines
11-reserved