3. Remove the nut and washer from the 14 inch threaded rod.
4. Drill a 5/8 inch hole through the top of an exterior wall.
5. Insert the 14 inch threaded rod through the hole in the wall. If the thickness of the wall is greater than 10 inches, a longer rod
may be required. Different lengths of rod are available at hardware stores. If a longer threaded rod is needed, use a 5/8"-11
threads per inch rod.
6. Place the nut and metal plate over the rod.
7. Tighten the square nuts to an approximate torque of approximately 55 ft-lbs.
8. Drill a second 5/8 inch (1.59 cm) hole 2.5 ft. (0.76 m) directly below the first hole.
9. Ensure both clamps are vertically aligned, as shown below