APV
APV_DE3_UK-7_082017.indd
9.3.
DN
40
50
120
65
219
80
296
100
505
125
800*
150
1200*
Inch
1,5"
2"
100
2,5"
170
3"
213
4"
490
6"
1150*
* no measuring value
Double Seat Valve
DELTA DE3
Instruction manual: UK - rev. 7
9.
Technical Data
57
47
9.4.
DN
25
40
50
65
80
100
125
150
Kvs - values in m³/ h
46
95
148
200
320
500*
700*
70
73
122
160
294
670*
Air consumption
actuator at
6 bar pneum. pressure
in NL / stroke
Inch
1"
0,9
1,5"
1,1
2"
1,3
2,5"
1,3
3"
1,3
2,3
4"
2,3
4,0
6"
6,4
23
42
69
120
164
300
360
21
43
59
71
150
340
Closing times
in sec.
hose length
1 m
1,5
1,5
1,5
1,5
1,5
3,0
3,0
5,0
8,0
UK
25
45
78
130
170
330
380
24
46
66
80
160
360
10 m
2,5
2,5
2,5
2,5
2,5
4,0
4,0
6,0
9,0
12
Need help?
Do you have a question about the APV DELTA DE3 and is the answer not in the manual?
Questions and answers