Kvs Values; Air Consumption / Switching Times - SPX FLOW APV DA4 Instruction Manual

Double seat mix proof valve
Table of Contents

Advertisement

APV
APV_DA4_UK-1_102018.indd
DN
40
50
65
80
100
Inch
1,5"
2"
2,5"
3"
4"
Actuator
NL/stroke
DN
Inch
valve open
40
1,5"
50
2"
2,5"
65
3"
80
4"
100
16
9.
Technical Data
9.3.
Kvs values in m³/hr
48
91
184
205
335
42
83
147
183
329
9.4.

Air consumption / Switching times

Air consumption at 5 bar
NL/stroke
upper seat lift
1,7
3,4
1,8
3,4
2,0
3,4
2,0
3,4
3,7
7,7
3,7
7,7
44
75
150
170
246
38
71
122
160
237
Seat lift actuator
NL/stroke
lower seat lift
0,3
0,3
0,3
0,3
0,4
0,4
24
48
74
131
170
24
46
67
83
167
Switching times in seconds
at 5 bar / CU43
Open
1,5
1,5
1,7
1,7
2,6
2,6
Double Seat Mix Proof Valve
Instruction Manual: UK - rev. 1
UK
24
46
74
126
156
23
46
67
82
156
Closed
1,8
1,8
2,0
2,0
3,3
3,3
APV DELTA DA4