1.

Product description

1.1 -

Commissioning

To start-up the system, the following steps must be carried out:
1 - Connect the power supply, compatible gearmotors (see Par graph
3.1, dip 1 and 2 setting) and desired accessories as indicated in
Paragraph 2.
2 - Set the dip switches (par. 3.1) and trimmers (par. 3.2) according
to the desired typs of operation and the system's structural con-
figuration.
3 - Memorise the transmitters (Paragraph 4).
4 - Programme the basic gate path (Paragraph 5) so that the control
unit learns the manoeuvre's start and end points.
5 - Perform the checks described in the "Testing and commissioning"
paragraph (Paragraph 6).
If, after completing these steps, the control unit should
malfunction, consult Paragraph 7, "Status signalling LEDs", to
identify any anomalies, and Paragraph 9, "Troubleshooting",
to attempt to solve them.
1.2 -

Main features

- Automated access command for 1 or 2 24V motors.
The dip switches can be used to configure the control unit in rela-
tion to the operator.
- Flasher control with/without integrated intermittency function (Par-
agraph 8.2).
- Integrated management for electric locks 24V max. 15VA (Para-
graph 8.4).
This output can also be used to control courtesy lights (Paragraph 13).
- Double NC input for opening and closing limit switch (Paragraph 8.8).
- Inputs for start, stop and pedestrian opening wired commands,
customisable to open, stop and close (Paragraph 8.9).
- Double input for safety devices: "PHO1" during closing and "PHO2"
during closing and/or opening (Paragraph 8.5).
- Possibility of powering 24VDC accessories (Paragraph 8.6).
- Input for gate status pilot light signalling the position of the leaves
(Paragraph 8.7).
- Input for external antenna that can be used for increasing the
range of the transmitters (Paragraph 8.10).
- Staggered closing of gate leaves adjustable through the trimmer
(Paragraph 3.2).
- Pause time for automatic re-closing adjustable to between 0 and
180 sec. with trimmer (Paragraph 3.2).
- Obstacle sensitivity adjustment with trimmer (Paragraph 3.2).
- Motor force adjustment with trimmer (Paragraph 3.2).
- Incorporated radio receiver (433.92MHz), compatible with King-
Gates rolling transmitters.
- 6 signalling LEDs (Paragraph 7).
- Slow-speed opening and closing (customisable through dedicated
programming).
1.3 -
Technical features of the
control unit
Mains power supply*
Motor power supply
Warning light power supply
Gate pilot lamp power supply
Accessories' power supply
(photocells...)
Radio receiver frequency
Storable remote controls
Radio antenna input
Operating temperature
230 Vac ±10%, 50 - 60 Hz
24V DC 280W and 10A peak
motor
24V max 15W
24Vdc max 10 W
24 Vdc max 10 W
433.920 MHz
170
RG58
-20 ÷ 50 °C
1