Table of Contents

Advertisement

ROLLS
IT
Istruzioni ed avvertenze per l'installazione e l'uso
EN
Instructions and warnings for installation and use
FR
Instructions et consignes pour l'installation et l'utilisation
DE
Anleitung und Warnhinweise für die Installation und Nutzung
ES
Instrucciones y advertencias para la instalación y uso
PT
Instruções para instalação e programação
Made in Italy

Advertisement

Table of Contents
loading

Summary of Contents for King gates ROLLS

  • Page 1 ROLLS Istruzioni ed avvertenze per l’installazione e l’uso Instructions and warnings for installation and use Instructions et consignes pour l’installation et l’utilisation Anleitung und Warnhinweise für die Installation und Nutzung Instrucciones y advertencias para la instalación y uso Instruções para instalação e programação...
  • Page 2 La ditta declina ogni responsabilità per eventuali errori di stampa o trascrizione, riservandosi di apportare senza preavviso le modifiche che riterrà più opportune. Vietata la riproduzione parziale senza il consenso del Costruttore. Le misure fornite sono indicative e non vincolanti. La lingua di stesura originale è...
  • Page 3: Table Of Contents

    Contents 1. General warnings 11. Advanced programming (*) 1.1 - Safety warnings 12. Back-jump adjustment 1.2 - Installation warnings 13. AUX output programming 2. Product description 13.1 - Selection of AUX output and operating mode 2.1 - Operating limits 13.2 - Selection of the type of devices connected to “S1 Edge” 14.
  • Page 4: General Warnings

    General warnings 1.2 - Installation warnings 1.1 - Safety warnings • Before beginning the installation procedure, WARNING! check that this product is suitable for the intend- ed use (see sections 3.1 and 3.2). If it is not suit- This manual contains important instructions able, DO NOT proceed with the installation.
  • Page 5 (including children) with reduced physical, senso- ry or mental capabilities or who lack experience and knowledge, unless they have been given su- pervision or instruction concerning the use of the product by a person responsible for their safety. - The product is not intended as an intruder pro- tection system.
  • Page 6: Product Description

    ROLLS is a gearmotor designed for the automation of sectional and overhead doors. ROLLS operates using electric power, in the event of a power failure from the electrical network, it is possible to release the gearmotor and move the door manually.
  • Page 7: Main Features Of The Control Unit

    (Paragraph 10.3). Power supply 230Vac ±10%, 50-60 Hz This output can also be used to control courtesy lights (Para- Rolls 700: 24V DC 120W graph 13). Motor power supply Rolls 1200: 24V DC 150W Inputs for start, stop opening wired commands, (Paragraph 10.7).
  • Page 8: Installation

    Fit a suitable interlock system if necessary. The manufacturer recommends a 50% margin on the force, as un- • Only insert the ROLLS plug into sockets equipped with a safety favourable climatic conditions may cause an increase in the friction.
  • Page 9: Assembly Of The Supplied Grb3 Guide

    3.2.2 - Assembly of guide supplied GRB3 The GRB3 guide is already assembled. All you have to do is tension- ing the belt using the M8 nut [F] (fig. 13).
  • Page 10: 3.2.3 - Fitting The Gearmotor To The Guide

    06. Drill at the outlined points and then, using a ladder, rest the brackets against the drilled holes (fig. 17) and secure using screws 01. Fit the ROLLS gearmotor output shaft to the guide head [A] and and plugs suited to the support surface (fig. 18).
  • Page 11: Installation Of Other Devices

    Check the devices which 04. Refer to fig. 28 and the connection descriptions in table 5 when can be connected to ROLLS in fig. 1 and in section 3.5 (“Description making the connections: of electrical connections”). - - if using the flashing light aerial, remove the wire clip (connected to terminal 14 as standard) and connect the RG58 shielded cable.
  • Page 12: Description Of The Electrical Connections

    ROLLS must be connected to the supply mains by a qualified electrician. 24 V To test ROLLS, just insert the plug into a power outlet, using an ex- S1 Edge tension if necessary (fig. 29). 24 V F 10AL F 3.15AL...
  • Page 13: Control Unit Setting

    Control unit setting 4.1 - Dip-switch adjustment If the dip-switch is put to ON, the automatic re-closing function is ac- tivated. The control unit automatically closes the leaves after the time set through the "PAUSE” potentiometer (see Paragraph 4.2). If the “AUTO”...
  • Page 14: Transmitter (Remote Control Unit) Programming

    5.2 - Programming the button linked lo4K”, “Stylo2K”, DigyPad, Myo C4, NovoTX, NovoDigy series by King Gates. See pictures below. to the “AUX” output This procedure allows you to program the radio control connected to the "AUX" output (output not active at the factory).
  • Page 15: Programming The Button Linked To The On-Board Courtesy Light

    5.3 - Programming of the button linked 5.5 - Deleting a single transmitter to the on-board courtesy light This operation deletes a single transmitter from the memory. This procedure allows for programming the button of the radio con- STEP ACTION RESULT trol linked to the on-board led courtesy light.
  • Page 16: Programming The Door Path

    Programming the door path 6.1 - Basic programming of the automation’s movement Through this procedure, the control unit memorizes working times and power required for opening and closing the system. The slowdown points are automatically set to ensure a cor- rect arrival to the end of gate path.
  • Page 17: Advanced Programming Of The Automation's Movement

    6.2 - Advanced programming of the DURING MOVEMENT: automation’s movement PRESS THE SET BUTTON OR A BUTTON OF A PROGRAMMED With this procedure, the control unit memorizes the times and power TRANSMITTER OR required for opening and closing the system. The yellow CLOSE THE WIRED Moreover, this procedure allows for setting:...
  • Page 18: Testing And Commissioning

    RED RADIO LED: - flashes when a command is received through King Gates trans- mitter is on in fixed mode when the control unit is in a radio program-...
  • Page 19: Reset Procedure

    In standby mode, the LEDs shows the current error type with a series of regular flashes according to the following scheme: Number of Error description flashes per series On-board memory fault Photo-test of safety devices failed. See Para- graph 4.1 for solving the problem. Automation’s movement programming re- quired.
  • Page 20: Devices Connectable To The Control Unit

    - during the opening phase they do not intervene 10.6 - with the opened door they lock closing commands - with the door closed they allow opening Figures 38a, 38b and 38c show examples of King Gates “Viky30” 10.1 - 10.2 photocell connections. 10.3 When multiple devices are connected on this contact, they must be connected in series (see Fig.
  • Page 21: 24Vdc Accessories' Power Supply

    For extending the reception range, an external antenna can be con- 0V (7) 0V (7) nected (present in the King Gates flashing lights range). +VA (8 or 10) +VA (8 or 10) If an external antenna is connected, the wire connected in series must be disconnected.
  • Page 22: Advanced Programming

    Advanced programming (not required for standard installation) Advanced programming The control unit has additional special features not required for most of standard installations. All descriptions are reported here below. Backjump adjustment This procedure allows for adjusting or eliminating the backjump. The yellow “set”...
  • Page 23: Aux Output Programming

    Advanced programming (not required for standard installation) AUX output programming These programming sequences are not essential for system opera- tion, but allow the AUX output to be activated by choosing the rele- PRESS THE SET AND RADIO The LEDs return to BUTTONS SIMULTANEOUSLY OR vant terminals.
  • Page 24: Selection Of The Type Of Devices Connected To "S1 Edge

    Other functions 13.2 - Selection of the type of devices connected to “S1 Edge” Default = “S1 Edge” set for devices with normally closed con- tact (terminal 9) To interrupt the following programming sequences at any This procedure allows for setting the “S1 Edge” output for managing time, press the SET and RADIO buttons simultaneously or 8.2kOhm resistive edges.
  • Page 25: F.a.q

    F.A.Q Problem Symptoms / Causes Solution 9a The control unit LEDs are No power to the control unit. Check the mains voltage. turned off For solar/battery power, check the 24V supply to the board. The fuses blown. You must disconnect Replace the fuses.
  • Page 26: Disposal

    Disposal 16.1 - Scrapping the product This product is made of various types of materials, some of which can be recycled while others must be scrapped. Seek information on the recycling and disposal systems envisaged by local regulations in your area for this product category. WARNING! - Some parts of the product may contain polluting or hazardous substances which, if released into the environ- ment, constitute serious environmental and health risks.
  • Page 27: Technical Specifications

    Technical specifications King Gates srl, in order to improve its products, reserves the right to modify their technical specifications at any time without prior notice. In any case, the manufacturer guarantees their functionality and suitability for the intended purposes. All the technical characteristics refer to a room temperature of 20°C (±5°C).
  • Page 28: Ce Declaration Of Conformity

    Type of product: Electromechanical gearmotor for sectional doors with control unit and receiver Model/Type: ROLLS 700 NG ROLLS 1200 NG Accessories: refer to the catalog The undersigned, Giorgio Zanutto, in the role of Chief Executive Officer, declares under his sole responsibility, that the product specified above conforms to the provisions of the following directives: •...
  • Page 29 Dati dell’installatore / Installer details Azienda / Company Timbro / Stamp Località / Address Provincia / Province Recapito telefonico / Tel. Referente / Contact person Dati del costruttore / Manufacturer's details King Gates S.r.l. Phone +39.0434.737082 Fax +39.0434.786031 info@king-gates.com www.king-gates.com...