13. FOR SLOWING DOWN THE CLOSING PHASE, DURING THE MOVEMENT
PRESS THE
SET BUTTON OR A PROGRAMMED TRANSMITTER BUTTON FOR
SETTING THE SLOWDOWN START POINT. ALTERNATIVELY, WAIT UNTIL THE
MOVEMENT HAS BEEN COMPLETED
The yellow "set" LED stays on in the fixed mode
In the event of motors for hinged leaf (see DIP1 and DIP2 setting), the
control unit will open and close one leaf at a time.
If the "POWER" trimmer is varied, the gate path must be reprogrammed.
If the operator does not recognise the mechanical stops even with the
OBS trimmer set to its minimum, you can select the open and closed points
during programming by pressing the "SET" button at the end of points 6, 9
and 13. In the event of two gate leaves, use the "SET" button for both leaves.
TABLE A
Procedure 1: REVERSING THE DIRECTION OF THE GATE SECTION 1 OPENING STROKE
1. PRESS THE RADIO
BUTTON
FOR 3 SECONDS
The yellow "set" LED flashes
fast
Procedure 2: REVERSING THE DIRECTION OF THE GATE SECTION 2 OPENING STROKE
1. PRESS THE START
BUTTON
FOR 3 SECONDS
The yellow "set" LED flashes
fast
6.

Testing and commissioning

Once the programming sequence has been completed, verify that:
- the motors switch off after a few seconds once the opening or closing phases end;
- the control unit responds to any and all wired commands: "START" (terminal 15), pedestrian opening (terminal 18) and "STOP" (terminal 17);
- the control unit responds to any programmed radio controls;
- the safety devices connected to"PHO1" (terminal 5) intervene while the gate closes and prevent the open gate from closing;
- the safety devices connected to"PHO2" (terminal 6) intervene while the gate opens and prevent the closed gate from opening;
If the "PHO2" dip-switch is put to ON, check that they intervene also when the gate closes and that they prevent the open gate from closing.
2. LEAF 1 MOVES
TO VERIFY
THAT THE MOTOR OPENS
The yellow "set" LED flashes
2. LEAF 2 MOVES
TO VERIFY
THAT THE MOTOR OPENS
The yellow "set" LED flashes
14. THE CONTROL UNIT COMPLETES
THE CLOSING PHASE
The yellow "set" LED turns off
15. END OF THE PROGRAMMING PRO-
CEDURE
The LEDs return to the normal operation
configuration
3. THE CONTROL UNIT
RETURNS TO STAND-BY MODE
FOR 8 SECONDS
(Point 5 of the programming sequence)
The yellow "set" LED flashes
3. THE CONTROL UNIT
RETURNS TO STAND-BY MODE
FOR 8 SECONDS
(Point 5 of the programming sequence)
The yellow "set" LED flashes