Control Unit Settings; Dip-Switch Adjustment - King gates STARG8 24 Installation And Use Instructions And Warnings

Control unit for 24v motor for sliding gates, or for one or two 24v motors for swinging gate
Hide thumbs Also See for STARG8 24:
Table of Contents

Advertisement

3.
Control unit setting
3.1 -

Dip-switch adjustment

2
ON
1
8
DIP
DIP-SWITCH status
DIP 1-2
ON ON
MOTOR
ON OFF
OFF ON
OFF OFF
DIP 3
ON
STEP
OFF
DIP 4
ON
AUTO
OFF
DIP 5
ON
PHO2
OFF
DIP 6
ON
HAZ
OFF
DIP 7
ON
FAST
OFF
SWINGING
(see DIP 1-2)
DIP 8
FUNC
SLIDING
(see DIP 1-2)
A variation of DIP 1-2 "MOTOR" and DIP 8 "FUNC" (if the
control unit is set to sliding gate) will not become effective
until a new gate path is programmed (Paragraph 5).
DIP1-2 "MOTOR":
Set DIP 1 and 2 in relation to the connected gearmotor. Depending
on the selected gearmotor, the control unit may set backjumps at
the end of the gate's travel and vary the power supply to the motors.
DIP3 "STEP":
If the dip-switch is put to ON, the step-by-step operating mode is
activated. At every start pulse (wired or via transmitter), the control
unit performs an action. Starts the motor if the automation system is
stopped, and stops it if it is moving. If the "STEP" dip-switch is put
to OFF, the OPEN FULLY/PAUSE/CLOSE FULLY/STOP operating
mode is activated (apartment block). The control unit only accepts
commands (either wired or via transmitter) for the opening phase.
Starts again from zero with the set delay when the automation sys-
tem is open. With the automation in the opening phase, it continues
6
DIP SWITCHES
(Paragraph 3.1)
Description of operation
Connected gearmotors: swinging series "Jet 24V", "Linear 24V", "Intro 24-400" or "Couper24"
Connected gearmotors: "Modus" series swing gate
Connected gearmotor: sliding series "Dynamos 24V"
Connected gearmotor: swinging series "Minimodus"
Step-by-step command mode: Open / Stop / Close / Stop
Command mode: opening only, if automatic closing is activated
Automatic closing activated (time set with the "Pause" trimmer)
Automatic closing deactivated
Safety devices connected to "PHO2" set as photocells (movement stopped during opening and
closing)
Safety devices connected to "PHO2" set as edges (reverse of opening movement)
Intermittent warning light power supply
Fixed warning light power supply
Immediate re-closing after intervention of "PHO1" photocells
No intervention of the photocells during re-closing
ON
Ram function enabled
OFF
Ram function disabled
ON
Reverse opening direction (the system must be programmed afterwards)
OFF
Reverse opening direction (the system must be programmed afterwards)
to open, and with the system in the closing phase it reopens fully.
The automation can re-close with the time set through the "PAUSE"
trimmer, if the "AUTO" dip-switch is set to ON. If not, it is necessary
to give a START command (either wired or via transmitter) with the
automation fully open.
DIP4 "AUTO":
If the dip-switch is put to ON, the automatic re-closing function is
activated. The control unit automatically closes the leaves after the
time set through the "PAUSE" trimmer (see Paragraph 3.2). If the
"AUTO" dip-switch is put to OFF, the automatic re-closing function
is deactivated. To close the leaves, therefore, a command must be
given (either wired or via transmitter).
DIP5 "PHO2":
If the dip-switch is put to ON, the safety devices for the opening
phase (see Paragraph 8.6) are set as photocells: they intervene dur-
ing both the opening and closing phases, by locking the movement
of the leaves and resuming the movement once they are released.