2.

Product description

ROLLS is a gearmotor designed for the automation of sectional and overhead doors.
ROLLS operates using electric power, in the event of a power failure from the electrical network, it is possible to release the gearmotor and
move the door manually.
2.1 -

Operating limits

Chapter 16 ("Technical specifications") provides the data needed to determine whether the product is suitable for the intended application.
Its structural characteristics make it suitable for use on sectional and overhead doors within the limits shown in table 1.
Model:
ROLLS 700
ROLLS 1200
The effective suitability of ROLLS for automating a specific door depends on the degree of door leaf balancing, guide friction and other as-
pects, including occasional phenomena such as wind pressure or the presence of ice, which could obstruct leaf movement.
To establish effective conditions, the force required to move the leaf throughout its stroke must be measured to ensure that this value does not
exceed the "nominal torque" specified in section 16 ("Technical specifications"); also, to avoid overheating, the control unit provides a limiter
based on engine effort and cycle duration, that intervenes when
the maximum limit is exceeded.
N.B.: 1 kg = 9.81 N, for example, 500 N = 51 kg
2.2 -

Typical system

Fig. 1 shows a typical system for automating a sectional door
a ROLLS
b Photocells
2.3 -

List of cables

Table 2 shows the specifications of the cables needed to connect up the various devices.
The cables used must be suitable for the type of installation, for instance an H03VV-F type cable is recommended for indoor applications.
Connection
Flashing light with aerial
Photocells
Key-operated selector switch
Note 1: a single 4x0.5 mm
2
32
Table 1 - ROLLS gearmotor operating limits
SECTIONAL door
Height: 3.7 m
Height: 3.7 m
Table 2 - List of cables
Cable type
No.1 2x0.5 mm
1 RG58 type shielded cable
No. 1 2x0.25 mm
No. 1 4x0.25 mm
No. 2 2x0.5 mm
cable can be used instead of two 2x0.5mm
Surface: 12 m
Height: 3.7 m
2
Surface: 23 m
Height: 3.7 m
2
c Main edge
d Flashing light with in-built aerial
e Key-operated selector switch
cable
2
cable for TX
2
cable for TX
2
cables (note 1)
2
cables.
2
Overhead door
Surface: 10 m
Surface: 14 m
Maximum length allowed
20 m
20 m (recommended less than 5 m)
30 m
30 m
50 m
2
2