  • Page 1 ELEVO Instructions and warnings for installation and use Made in Italy...
  • Page 3: Table Of Contents

    3.2.4 - Mounting the gearmotor to the ceiling 3.3 - Installation of other devices 3.4 - Electrical connections 3.5 - Connecting ELEVO to the mains 3.6 - Description of the electrical connections 4. Control unit setting 4.1 - Dip-switch adjustment 4.2 - Knob adjustment...
  • Page 4: General Warnings

    General warnings ations. If this were to happen, stop installation immediately and contact KING-gates Customer Service. 1.1 - Safety warnings - Do not make alterations to the product in any way. Improper use can only lead to malfunctions. CAUTION! The manufacturer declines all liability for damage - This manual contains important safety in- caused by arbitrary modifications to the product.
  • Page 5: Product Description

    ELEVO The measurements in table 2 are to be taken as a guideline and are for general estimate purposes only. The effective suitability of ELEVO for automating a specific door depends on the degree of door leaf balancing, guide friction and other aspects, including occasional phenomena such as wind pressure or the presence of ice, which could obstruct leaf movement.
  • Page 6: Main Features Of The Control Unit

    2.4 - Main features of the control unit 2.5 - Technical features of the control unit Automated access command for 1 24V motor. Flasher control with/without integrated intermittency function (Paragraph 10.3). Mains power supply* 230 Vac ±10%, 50-60 Hz Integrated management for electric locks 24V max. 15VA (Para- 110W and 10A peak graph 10.4).
  • Page 7: Installation

    Fit a suitable interlock system if necessary. and the directions provided in this manual. • Only insert the ELEVO plug into sockets equipped with a safety 3.1 - Preliminary checks grounding system.
  • Page 9: 3.2.3 - Fitting The Gearmotor To The Guide

    04. Using a ladder, lift the gearmotor until the brackets are touching the ceiling. Trace the drilling points and then return the gearmotor to 01. Fit the ELEVO gearmotor output shaft to the guide head [A] and the ground. secure using 4 M6.3x38 screws [G] (fig. 14). The gear motor rotates and can be positioned in three different ways (fig.
  • Page 10: Installation Of Other Devices

    Check the devices which making the connections: can be connected to ELEVO in fig. 1 and in section 3.5 (“Description - if using the flashing light aerial, remove the wire clip (connected to of electrical connections”).
  • Page 11: Connecting Elevo To The Mains

    11 - 12 Lock / AUX Default: electric lock 12V max.15W (for courtesy light To test ELEVO, just insert the plug into a power outlet, using an ex- tension cord if necessary (fig. 29). enable, see par. 13. 13 - 14...
  • Page 12: Control Unit Setting

    Control unit setting DIP2 “AUTO”: If the dip-switch is put to ON, the automatic re-closing function is ac- tivated. The control unit automatically closes the leaves after the time set through the “PAUSE” knob (see Paragraph 4.2). If the “AUTO” 4.1 - Dip-switch adjustment dip-switch is put to OFF, the automatic re-closing function is deac-...
  • Page 13: Trasmitter (Remote Control Unit) Programming

    The red “radio” LED turns lo4K”, “Stylo2K”, DigyPad, Myo C4, NovoTX, NovoDigy series BUTTON FOR 1 SECOND on in the fixed mode by King Gates. See adjacent pictures. The red “radio” LED PRESS THE START remains lit in fixed mode BUTTON FOR 1 SECOND and the red “error”...
  • Page 14: Deleting All Memorised Transmitter

    5.4 - Deleting all memorised transmitter ON THE TRANSMITTER This operation deletes all memorized transmitters from the memory. YOU WANT TO PROGRAM, HOLD DOWN BUTTONS 1 STEP ACTION RESULT AND 2 TOGETHER FOR PRESS THE RADIO 4 SECONDS BUTTON FOR 4 The red “radio”...
  • Page 15: Programming The Door Path

    Programming the 6.1 - Basic programming of the automation’s movement door path Through this procedure, the control unit memorizes working times and power required for opening and closing the system. The slowdown points are automatically set to ensure a correct arrival to the end of gate path.
  • Page 16: Advanced Programming Of The Automation's Movement

    6.2 - Advanced programming of the If the “FORCE” knob is adjusted, the automation’s move- automation’s movement ment must be reprogrammed. The red “Error” LED flashes during the automation’s With this procedure, the control unit memorizes the times and power movement when a mechanical stress point is detected (this required for opening and closing the system.
  • Page 17: Led Indication

    RED RADIO LED: All LED light up in series BUTTON FOR 3 SECOND - flashes when a command is received through King Gates transmitter The red “ERROR” LED is on in fixed mode when the control unit is in a radio programming...
  • Page 18: Devices Connectable To The Control Unit

    10.1 10.2 10.2 - with the closed door they lock opening commands 10.1 10.2 Figures 38a, 38b and 38c show examples of King Gates “Viky30” 10.2 photocell connections. 10.1 10.2 When multiple devices are connected on this contact, they must be series connected (see Fig. 38c).
  • Page 19: 24V Accessories' Power Supply

    Receiver Transmitter For extending the reception range, an external antenna can be con- pair 1 nected (present in the King Gates flashing lights range). pair 1 If an external antenna is connected, the series connected wire must be disconnected. Receiver...
  • Page 20: Advanced Programming

    Advanced The yellow “set” LED PRESS THE RADIO remains lit in the fixed programming BUTTON FOR 2 ECONDS mode and the red “error” LED flashes fast PRESS THE SET AND RADIO BUTTONS The LEDs return to The control unit has additional special features not required for most SIMULTANEOUSLY OR the normal operation of standard installations.
  • Page 21: Aux Output Programming

    AUX output 13.1 - Selection of device connected to “Lock/AUX” output programming Default = electric lock This procedure allows for setting the “AUX” output for the operation These programming sequences are not essential to the system’s op- ELECTRIC LOCK: the control unit closes the AUX contact (termi- eration, though they allow for setting the type (lock or courtesy light), nals 11-12) whenever a command is received.
  • Page 22: Selection Of "Lock/Aux" Output Operating Mode

    13.2 - Selection of “Lock/AUX” 13.3 - Selection of “AUX” output operating mode output voltage IF THE “AUX” OUTPUT IS SET AS COURTESY LIGHT (see Par- STAR EVO: Default=12V agraph 13.1) The output voltage of the AUX contact can be set to 12V , depending on the connected lock or the available relay.
  • Page 23: Selection Of The Type Of Devices Connected To "S1 Edge

    Other functions 13.4 - Selection of the type of devices connected to “S1 Edge” To interrupt the following programming sequences at any Default = “S1 Edge” set for devices with normally closed con- tact (terminal 9) time, press the SET and RADIO buttons simultaneously or wait 10 seconds.
  • Page 24: F.a.q

    F.A.Q Problem Symptoms / Causes Solution 9a The control unit LEDs are No power to the control unit. Check for mains power – see Paragraph 3.4 / 3.5. turned off For solar/ battery power check 24V power to the board. The fuses blown.
  • Page 25: Technical Specifications

    Technical specifications King Gates srl, in order to improve its products, reserves the right to modify their technical specifications at any time without prior notice. In any case, the manufacturer guarantees their functionality and suitability for the intended purposes. All the technical characteristics refer to a room temperature of 20°C (±5°C).
  • Page 26: Ce Declaration Of Conformity

    CE Declaration of conformity and declaration of incorporation of “partly-completed machinery” Note: the contents of this declaration correspond to that stated in the official document filed in the offices of KING Gates S.r.l. and, in particular, to the latest version thereof available prior to the printing of this manual.
  • Page 28 Dati dell’installatore / Installer details Azienda / Company Timbro / Stamp Località / Address Provincia / Province Recapito telefonico / Tel. Referente / Contact person Dati del costruttore / Manufacturer's details King Gates S.r.l. Phone +39.0434.737082 Fax +39.0434.786031 info@king-gates.com www.king-gates.com...