Advanced Programming Of The Automation's Movement - King gates STARG8 24 Installation And Use Instructions And Warnings

Control unit for 24v motor for sliding gates, or for one or two 24v motors for swinging gate
Hide thumbs Also See for STARG8 24:
Table of Contents

Advertisement

5.3 -

Advanced programming of the automation's movement

With this procedure, the control unit memorises the times and power required for opening and closing the system.
Moreover, this procedure allows for setting:
- start point of gate deceleration area or its deletion
- reverse direction of travel
7
LEAF 1
(gate leaf that opens first, by
default the motor is connected
to the "MOTOR 1")
Prior to proceeding with the programming procedure, verify that dip-switches 1 and 2 have been correctly set.
Once programming is complete, the reverse motor direction settings will remain in force until the control unit is reset or
professionally reprogrammed.
DIP
DIP-SWITCH status
DIP 1-2
ON ON
MOTOR
ON OFF
OFF ON
OFF OFF
1. PUT THE GATE LEAF/LEAVES
IN THE INTERMEDIATE
POSITION
7. PRESS THE
SET BUTTON OR
A PROGRAMMED TRANSMITTER
BUTTON
The yellow "set" LED stays on
8. THE CONTROL UNIT PER-
FORMS THE OPENING
MOVEMENT
The yellow "set" LED stays on
12. THE CONTROL UNIT PER-
FORMS
A FULL CLOSING MOVEMENT
The yellow "set" LED stays on
12
Description of operation
Connected gearmotors: swinging series "Jet 24V", "Linear 24V", "Intro 24-400" or "Couper24"
Connected gearmotors: "Modus" series swing gate
Connected gearmotor: sliding series "Dynamos 24V"
Connected gearmotor: swinging series "Minimodus"
2. PRESS THE SET BUTTON
FOR 2 SECONDS
The yellow "set" LED flashes
(if not, consult Paragraph 16.1)
6. THE CONTROL UNIT PERFORMS A
FULL CLOSING MOVEMENT
The yellow "set" LED stays on
9. FOR SLOWING DOWN THE OPENING PHASE, DURING THE MOVEMENT PRESS THE
SET BUTTON OR A PROGRAMMED TRANSMITTER BUTTON TO SET THE SLOWDOWN
START POINT. ALTERNATIVELY, WAIT UNTIL THE MOVEMENT HAS BEEN COMPLETED
11. PRESS THE SET
BUTTON OR A PROGRAMMED
TRANSMITTER BUTTON
The yellow "set" LED stays on
(gate leaf that opens second, by
default the motor is connected
to the "MOTOR 2")
3. PRESS THE RADIO BUTTON
The yellow "set" LED turns on
4. THE CONTROL UNIT PARTLY OPENS
The yellow "set" LED flashes
5. THE CONTROL UNIT WAITS FOR THE
MOTORS TO CHANGE THE DIRECTION
OF THEIR OPENING MOVEMENT FOR
8 SECONDS (SEE TABLE A)
The yellow "set" LED flashes
The yellow "set" LED stays on
10. THE CONTROL UNIT COMPLETES
THE OPENING PHASE
The yellow "set" LED stays on
LEAF 2
FOR 1 SECOND
in the fixed mode
THE GATE
OR PRESS SET
TO PROCEED

Advertisement

Table of Contents
loading

Table of Contents