Description Of Menu 6 Functions; Description Of Menu 7 Functions - Ikegami HTM-1917R Operation Manual

Hdtv/sdtv multi format
Hide thumbs Also See for HTM-1917R:
Table of Contents

Advertisement

(8) Description of MENU 6 Functions

MENU6 <SETUP(ASP-80)>
1.ZERO CARIBRATION
2.AWB(6500k)
3.AWB(9300k)
4.AWB(USER DATA)
5.MEASUREMENT & MEMORY
6.REAL TIME MEASUREMENT
NEXT →(MENU)
SELECT→(ENT) EXIT→(ESC)
For operation details, refer to the ASP-80 manual.
① Zero calibration
Perform the calibration of ASP-80.
Connect ASP-80 to the monitor, and make sure to
perform this calibration before proceeding onwards.
The function is disabled unless ASP-80 is con-
nected.
Be careful not to allow external light into the sen-
sor.
When the sensor is not receiving light to be mea-
sured, the message "ERROR 1 : TOO LIGHT" ap-
pears.
② Auto white balance (6500K)
Setup at 6500K
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.
③ Auto white balance (9300K)
Setup at 9300K
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.

(9) Description of MENU 7 Functions

* This menu is intended to control the embedded audio module DKM-511AV/AVD and the embedded audio level
meter module DAM-504/508.
The setting in this menu does not function for a monitor without the above modules.
MENU7 <AUDIO>
1.LINE OUT CH
CH1/2
2.LED ENABLE
CH1to8
3.LED DIMMER
HIGH
NEXT →(MENU)
SELECT→(ENT) EXIT→(ESC)
① Paired channel selection
Select the DKM-511AV analog audio line output
(2ch) from the four pairs of channels CH1/2, CH3/
4, CH5/6 and CH7/8.
This function is disabled for the embedded digital
audio output model (DKM-511AVD).
② Level meter channel selection
Select the display channel of DAM-504/508 from 8-
channel (CH1 TO 8), 6-channel (CH1 TO 6) and 2-
channel (CH1 TO 2) as necessary.
① Zero calibration
② Auto white balance (6500K)
③ Auto white balance (9300K)
④ Auto white balance (User data)
⑤ Color temperature/luminance measurement and memory
⑥ Real-time color temperature/luminance measurement
① Paired channel selection
② Level meter channel selection
③ Level meter brightness setting
35
④ Auto white balance (User data)
Setup at user color temperature.
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.
⑤ Color temperature and luminance measure-
ment and memory
Measure the color temperature, luminance and ras-
ter luminance of the user setting.
The results can be stored as USER DATA if neces-
sary.
Measurable ranges are as follows.
Luminance:
Raster luminance:
Color temperature (x, y coordinates):
⑥ Real-time color temperature and luminance
measurement
Color temperature and luminance are measured
for real-time display of the readings.
The function can also be applied to the measure-
ment of other devices.
For DAM-504 (4-channel model), the selections of
8-channel and 6-channel are disabled.
③ Level meter brightness setting
Select the brightness of DAM-504/508 level meter
LED from HIGH, MID, LOW and OFF.
The setting is not applied to the tally (red and
green).
10~190cd/ ㎡
0.01~0.99cd/ ㎡
0.250~0.380

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents