3. Installation

Caution: For your safety, turn off the power of each equipment before connection.

3-1. External connection

(1) Standard module (MPU, VIDEO PROCESS)
REMOTE
SERIAL
PARALLEL
PARALLE REMOTE signal input
• Connect the supplied remote connector here.
• For details of pin connection, refer to 3.2.
SERIAL REMOTE signal input
• Connect the BNC cable from the serial remote controller SRC-301Z here.
• By adopting the loop through connection method, up to 99 monitors can be controlled individual-
ly or together.
• If not adopting the loop through connection method, connect the terminated plug.
• Set the monitor ID in the MENU screen.
MPU module
Option module *Refer to the pages that follow.
VIDEO PROCESS module
YPbPr/RGB A channel input
YPbPr/GBR
• Input here an RGB signal or YPbPr signal.
CH A
• Input formats
① 480i/59.94
② 575i/50
Y/G
③ 480p/59.94 (option)
④ 1035i/59.94(60)
⑤ 1080i/59.94(60)
⑥ 1080i/50 (option)
⑦ 1080p/24sF8(23.98sF) (option)
⑧ 720p/59.94(60)
Pb/B
⑨ 720p/50 (option)
• Signal format
The signal format needs to be set at the MENU 1-2 HDTV/SDTV
item. For 1080i or 1035i, the MENU 1-3 1035i/1080i item also
needs to be set.
• Switch YPbPr/RGB at the MENU 1-4 item.
Pr/R
• If not adopting the loop through connection method, connect the
terminated plug.
SYNC
EXT SYNC signal input
• If inputting the YPbPr/RGB signal or component signal by external
sync, input the external sync signal here.
• If not adopting the loop through connection method, connect the
terminated plug.