⑤ Setting of CHANGE ASPECT
Associate the change of aspect settings with the
switching of inputs.
AUTO:
Display with the aspect ratio preset for
each channel.
MANUAL: Fixed aspect ratio without automatic
change along with channel switching.
Apply this setting if 4:3/16:9 switching
is done using parallel remote connec-
tion.
⑥ Setting of SET UP ON/OFF
Set SET UP to ON or OFF.
During SET UP, images are cut and reduced to 1/4
the normal height. Under this condition, adjust
R/G/B BACKGROUND until lines become just vis-
ible.
For details, refer to 4.6(3).
⑦ Setting of remote ID numbers
Set the monitor ID numbers ( 01 ~ 99 ).
When performing remote control operations using
wireless remote controller (RCT-30A) or serial re-
mote controller (SRC-301Z), the monitors can be
remote controlled individually with the ID num-
bers ( 01 ~ 99 ) assigned to the monitors.

(5)Description of MENU 3 Functions

MENU3 <CHANGE FILE>
1.SELECT FILE
2.STORE FILE
3.CHANGE FILE
4.LOAD FACTORY
NEXT →(MENU)
SELECT→(ENT) EXIT→(ESC)
① FILE selection
Select any of REFERENCE, FILE 1, FILE 2 and
FILE 3.
The four files store the following 9 types of data.
HUE, CONTRAST, R.BACKGROUND, CHROMA,
G.GAIN G.BACKGROUND, BRIGHTNESS, B.GAIN
B.BACKGROUND
The operation is the same as the FILE switch in
the drawer panel.
② Selection of destination FILE
The data (9 types) in the file selected in ① are all
transferred (overwritten) to the file selected here.
FILE selected in ①
... Transfer 9 types of data
FILE selected in ②
When ALL is selected, the data in the file selected
is transferred to all files (REF, FILE 1~3).
FILE1
① FILE selection
FILE3
② Selection of destination FILE
MANUAL
③ AUTO/MANUAL setting for FILE change
ALL
④ Setting to restore default (factory setting)
⑧ Setting of degauss ON timer
Set the operation start time of the degauss (de-
magnetization) function, which operates automati-
cally when the power is turned on, using 0 ~ 9
groups.
By setting in groups 0 to 9 , the overall rush
current which flows when the power of all devices
of the system are turned On can be minimized.
Timer operation
When set to 0, the degauss function will automati-
cally start about 4 seconds after the power is turned
on. The time delays with an increment of 0.5 sec-
onds each time the setting is increased by 1.
The table below shows the approximate time until
the degauss function starts after the power is
turned on.
Setting Operation Start Time
0
4.0 seconds
1
4.5 seconds
2
5.0 seconds
3
5.5 seconds
4
6.0 seconds
③ AUTO/MANUAL setting for FILE change
Set AUTO or MANUAL for switching the FILE set-
tings.
AUTO:
MANUAL:
④ Setting to restore default (factory setting)
Perform this setting to restore the default settings.
ALL:
PRESET:
MENU&SW: Factory settings are restored for all
33
Setting Operation Start Time
5
6.5 seconds
6
7.0 seconds
7
7.5 seconds
8
8.0 seconds
9
8.5 seconds
FILE setting for each channel is
changed automatically along with
channel switching.
FILE setting is fixed.
Factory settings are restored for all PRE-
SET data, all MENUs and switches.
Factory settings are restored for all
PRESET data.
MENUs and switches.