108 en | Keypad Installer menu
Module Hostname
1.
2.
3.
4.
5.
6.
20.1.8
[2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in
module)
You can use a B44x cellular communication module for communication. Plug it directly into the
control panel or use it with a B450 module.
Access Point Name
Access Pt Username
Access Pt Passcode
SIM PIN
Access Point Name
1.
2.
3.
4.
5.
Access Pt Username
1.
2.
3.
4.
5.
Access Pt Passcode
1.
2.
3.
2018.07 | 16 | F.01U.287.180
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [3] DNS Parameters > [3] Module Hostname. The keypad shows the current
hostname.
Press Edit or Enter to edit the hostname.
Delete the existing number, if necessary, and then enter the new number. Use
Previous or
/Next to move to a different byte.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
Module 1 settings
_______________________________
_______________________________
_______________________________
_______________________________
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [2] Network > [2] Cellular > (choose the SDI2 cellular
module or plug-in module) > [1] Access Point Name. The keypad shows the current
configuration.
Press Edit or Enter to edit the configuration.
Delete existing characters, if necessary, and then enter the new characters.
Press Save or Enter. The keypad shows Parameter saved.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [2] Network > [2] Cellular > (choose the SDI2 cellular
module or plug-in module) > [2] Access Pt Username. The keypad shows the current
configuration.
Press Edit or Enter to edit the configuration.
Delete existing characters, if necessary, and then enter the new characters.
Press Save or Enter. The keypad shows Parameter saved.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [2] Network > [2] Cellular > (choose the SDI2 cellular
module or plug-in module) > [3] Access Pt Password. The keypad shows the current
configuration.
Press Edit or Enter to edit the configuration.
Installation Manual
Control Panels
Module 2 settings
_______________________________
_______________________________
_______________________________
_______________________________
Bosch Security Systems, Inc.
/