en | Power supply
Warning!
High current arcs are possible
The positive (red) battery lead and the terminal labeled BAT+ can create high current arcs if
!
shorted to other terminals or the enclosure. Use caution when you touch the positive lead
and the terminal labeled BAT+. Always disconnect the positive (red) lead from the battery
before you remove it from the terminal labeled BAT+.
Caution!
Battery terminals and wire are not power limited
!
Maintain a 0.250 in (6.4 mm) space between the battery terminals, battery wiring, and all
other wiring. Battery wiring cannot share the same conduit, conduit fittings, or conduit
knockouts with other wiring.
Figure 6.1: Non-power-limited wiring (B5512 shown)
Callout ᅳ Description
1 ᅳ Conduit required for use with external batteries
2 ᅳ To UL listed class 2 transformer 18 VAC 22 VA 60 Hz
3 ᅳ 0.25 in (6.4 mm) minimum
4 ᅳ Battery terminals. BAT- is non-power limited
5 ᅳ Battery wires
6 ᅳ 12 V sealed lead-acid rechargeable battery (D126/D1218)
7 ᅳ Sensor loop wires
2018.07 | 16 | F.01U.287.180
2
1
COMMUNICATION MODULE 1
OUTPUT A
Jumper Under Cover
AUX PWR
COM
DRY
SDI2
OUTPUT A
Device Bus
R Y G B
AUX
18 VAC
BATTERY
OUTPUT A
- 12 V +
COM AUX
R
Y
NO C NC
18VAC
+ BAT -
PWR A
OUTPUT A
5
3
6
Installation Manual
ETHERNET
100BASE-T
LINK
USB
ON-BOARD POINTS
Voltage Ranges
C
Open
3.7 - 5.0 VDC
OUTPUT
Normal
2.0 - 3.0 VDC
B
Short
0.0 - 1.3 VDC
1 k
End of Line Resistors
1 COM 2
3 COM 4 5 COM 6
7 COM 8
G
B
1
COM
2
3
COM
4
5
COM
6
7
COM
8
B COM
4
Bosch Security Systems, Inc.