10. TABLE OF ERROR CODES
Version updating errors
Code
No control program for the operation
E870
panel is present.
Version update requests cannot be
E880
received.
Communication error was detected during
E881
version update.
No control program is present on the SD
E883
card.
There is a problem with the control
E884
program.
Writing of the control program cannot
E885
begin.
Data error occurred during writing of the
E886
control program.
Error occurred during writing of the control
E887
program.
If an error code that is not listed above appears or if carrying out the specified remedy does not solve the problem,
contact the place of purchase.
147
Cause
Remedy
Load the control program for the operation panel from the
SD card.
Turn off the power, and then check that there are no
problems with the wiring and the P.C. boards inside the
control box.
Turn off the power, and then repeat the version update
procedure.
If the error continues to occur, turn off the power, and then
check that there are no problems with the wiring and the
P.C. boards inside the control box.
Check that the control program has been saved into the
correct folder.
Write the correct file onto the SD card.
Turn off the power, and then check that there are no
problems with the wiring and the P.C. boards inside the
control box which are to have their firmware versions
updated.
Turn off the power, and then check that there are no
problems with the wiring and the P.C. boards inside the
control box which are to have their firmware versions
updated.
Turn off the power, and then check that there are no
problems with the wiring and the P.C. boards inside the
control box which are to have their firmware versions
updated.