Terminal Strip Connections; Routing The Cable Through The Boiler - Worcester GB162-65 Installation And Servicing Instruction

Wall hung gas fired condensing boiler
Table of Contents

Advertisement

INSTALLATION
8.5.2

TERMINAL STRIP CONNECTIONS

B Turn the vent key through a quarter rotation to undo
the boiler door lock (
B Push the fastener down (
boiler door.
Fig. 38
Open the boiler door
B Undo 1 screw to release the cover over the electrical
connections and pull the cover upwards (
Fig. 39
Pull up the cover over the electrical connections
The terminal strip in the boiler (fig. 40) has a number of
terminals to connect internal and external electrical
components. The listing below shows which
components must be connected to which terminals (see
section 7.5.4, page 36).
If uncertain how to connect controls to this
appliance, first contact the Worcester
technical helpline on 0844 892 3366 or your
supplier.
32
fig. 38, see detailed picture).
fig. 38) and open the
6 720 648 726-038.1TD
fig. 39).
6 720 648 726-039.1TD
FA
FW
DWV
RC
WA
EV
A
Fig. 40
Terminal strip
A
Low-voltage connections
B
230 V connections
8.5.3

ROUTING THE CABLE THROUGH THE BOILER

B Route the cable for the low-voltage connections
through the hole on the left [1].
B Route the cable for the 230 V-connections through the
hole on the right [2].
B Attach the cable for the 230 V-connections using the
strain relief clamps [3].
1
Fig. 41
Routing the cable
6 720 648 726 (2011/07)
Mains
PK
PS
PZ
230 V
B
6 720 648 726-040.1TD
3
2
6 720 648 726-041.1TD