B Connect the 230 V AC mains cable of the first module
to the next module.
The module may have the letters RC or EMS
above the connection [1].
1
To the 230 V AC mains plug
in the earthed socket or a
free connector in the boiler.
Fig. 65
Connecting several modules
B Connect the free connector of the EMS bus
connecting cable to the first module (
B If more modules are used, the EMS bus connection for
the second module may be branched off from the first
module using the cable enclosed with the module
(
fig. 65 and 66).
NOTE:
Pay attention to the polarity when using an
EMS bus connection cable..
B Connect the wire from terminal 1 to ter-
minal 1 and from terminal 2 to terminal 2
(
fig. 65 and 66).
Fig. 66
EMS bus polarity
6 720 648 726 (2011/07)
1
6 720 648 726-065.1TD
To a free connector in the
boiler or the terminal strip.
Note: This connection is not
reverse-proof.
fig. 64, [2]).
6 720 648 726-066.1TD
INSTALLING AND CONNECTING FUNCTION MODULES
OUTSIDE THE BOILER
B Install the module on the wall.
B Make a sufficiently long EMS bus connection cable,
using a 2-core cable of 0.4 - 0.75 mm² and the
connector enclosed with the module (
Important: Use the connector of the same colour as
the connections on the module.
NOTE:
Pay attention to the polarity when using an
EMS bus connection cable.
B Connect the wire from terminal 1 to ter-
minal 1 and from terminal 2 to terminal 2
(
fig. 65 and 66).
B Connect the EMS bus connection cable to the orange
connection of the terminal strip [1].
1
RC
Fig. 67
Terminal strip - Room controller RC and EMS bus
(connection colour orange)
B Connect the other end of the EMS bus connection
cable to the first module (
The module may have the letters RC or EMS
above the connection (
B If more modules are used, the EMS bus connection for
the second module may be branched off from the first
module using the cable enclosed with the module.
B Connect the EMS bus connection lead of the first
module to the next module (
B Make a sufficiently long 230 V AC mains cable, using
a 3-core cable of at least 0.75 mm² with an earthing
wire, the connector enclosed with the module and a
230 V AC earthed plug.
B Connect the 230 V AC mains cable to the module
(
fig. 65). If more modules are used, the 230 V AC
supply to the next module can be branched off from
the previous module using the connector enclosed
with the module and a 3-core 0.75-mm² current cable
with an earthing wire.
B Connect the 230 V AC supply cable of the previous
module to the next module (
INSTALLATION
fig. 66).
6 720 648 726-067.1TD
fig. 65).
fig. 65, [1]).
fig. 65).
fig. 65).
39