Safety; Please Observe These Instructions; Tools, Materials And Further Equipment; Recycling - Worcester GB162-65 Installation And Servicing Instruction

Wall hung gas fired condensing boiler
Table of Contents

Advertisement

SAFETY

4
SAFETY
Please observe these instructions for your own safety.
4.1
PLEASE OBSERVE THESE
INSTRUCTIONS
Observe the following instructions when installing and
operating the heating system:
• The local building regulations as regards the
installation conditions.
• The local building regulations as regards fresh air
supply and air exhaust facilities and flue connections.
• The regulations for electrical connections to the
power supply.
• The gas utility company rules for connecting the gas
burner to the local gas mains.
• The regulations and standards concerning the safety
facilities for the DHW/heating system.
• The installation instructions for producers of heating
systems.
DANGER:
Danger of fatal accident from explosive
fumes. If you smell gas, there is a danger of
explosion.
B No naked lights. No smoking. Do not use
lighters.
B DO NOT operate any device that is likely
to produce sparks. Do not operate any
electrical switches, including telephones,
plugs or doorbells.
B Shut off the main gas supply.
B Open doors and windows.
B Warn the residents but do not ring
doorbells.
B Contact the gas utility company from a
telephone located outside the building.
B If you can hear gas leaking out, evacuate
the building immediately, prevent other
persons from entering, and notify the
police and fire service immediately (from
a telephone OUTSIDE the building).
DANGER:
Danger of fatal accident from explosive
fumes.
B Only carry out work on gas pipes and
fittings if you are Gas Safe / ACS
registered.
14
DANGER:
Danger of fatal accident due to poisoning.
Dangerous flue gas can escape if the air
supply is insufficient.
B Make sure that air vents are not reduced
in size or obstructed.
B The boiler may only be operated after the
defect has been remedied.
B Warn the user of the system of the defect
verbally and in writing.
• The condensing gas boiler may only be used with the
combustion air/flue gas systems designed and
approved specifically for this type of boiler.
• Note: in certain areas permits are required for the flue
gas system and for connecting the condensate water
drain to the public sewage network.
4.2
TOOLS, MATERIALS AND FURTHER
EQUIPMENT
Boiler installation and maintenance requires standard
tools for heating, gas and water installation.
In addition you will need a hand truck/cart with a
securing strap.
4.3

RECYCLING

B Dispose of the boiler's packaging material in an
environmentally friendly manner.
B Dispose of those components of the heating
installation (e. g. boiler or controller) which have to
be replaced in an environmentally friendly manner by
handing them in at an authorised recycling facility.
6 720 648 726 (2011/07)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gb162-80Gb162-100

Table of Contents