Service Mode menu
[\/2/4|
Step 1
Display value. Currently measured CH flow temperature in °C. Also see
section 14.2, page 70.
Step 2
Activate service mode?
Step 3
To activate service mode 1st step:
Press and hold the
[\/2/4]
Step 4
Display value. As soon as a non-flashing dot is shown in the right-hand
bottom corner of the display, the boiler is in heating mode at a capacity of
100 % for a maximum of 30 minutes. The maximum CH flow temperature
as set on the maximum CH flow temperature dial of the BC10 basic
controller (control panel) now applies.
Step 5
To activate service mode 2nd step:
Simultaneously press and hold the
[l/-/-]
Step 6
Display setting. Maximum capacity setting during heating mode in %.
Also see section 14.3, page 71. In this case: [l/-/-] = 100 %. Service mode
has been activated. You can now temporarily lower the boiler performance
to partial load to check and if relevant set the gas/air ratio or the
ionisation current.
Step 7
Press and hold the
[l/2/0] with a 65 and 100-kW boiler.
[l/2/5]
Display setting: with a 80-kW boiler and [l/2/0] with a 65 and 100-kW boiler.
Step 8
Minimum capacity setting during heating mode in %. Also see
section 14.3, page 71. The boiler will reduce its performance to 25 % or
20 % respectively within a couple of seconds. The maximum CH flow
temperature set on the BC10 basic controller (control panel) applies now.
Check the gas/air ratio or the ionisation current and if necessary set the
gas/air ratio according to subsection 10.2.7 or subsection 10.2.11.
e
Step 9
Press the
[f/\/5|
Step 10
Display setting: This parameter shows the pump run-over time in minutes
when heating mode has been ended. Also see section 14.3, page 71.
e
Step 11
Press the
[c/\/1|
Step 12
Display setting: This parameter indicates the DHW mode status setting.
Also see section 14.3, page
e
Step 13
Press the
[\/2/4|
Step 14
Display value. Currently measured CH flow temperature in °C.
Also see section 14.3, page 71.
e
Step 15
Press the
[p/1.6|
Step 16
Display value. Currently measured system pressure in bar.
Also see section 14.3, page 71.
e
Step 17
Press the
[-/a/\|
Step 18
Display code: Operating phase: The boiler is in service mode.
Also see section 14.3, page 71.
e
Step 19
Press the
Table 11 Service mode
6 720 648 726 (2011/07)
d
button for more than 2 but not longer than 5 seconds
d
+
button until the display shows [l/2/5] with a 80-kW boiler or
c
button.
button.
71..
button.
button.
button.
button.
e
buttons for more than 2 seconds.
OPERATION
Yes:
step 3
No:
step 1
43