Worcester GB162-65 Installation And Servicing Instruction page 80

Wall hung gas fired condensing boiler
Table of Contents

Advertisement

DISPLAY INFORMATION
Main
Sub
display
display
z
z
code
code
[a/1/8|
[8/2/5|
e
e
e
[a/2/1|
e
[8/0/6|
[a/2/1|
[8/1/6|
e
e
[a/2/2|
[8/0/6|
e
e
Table 24 Display codes
80
Display codes
Display code
Key to display code
z
e
Fault:
Conflicting addresses. Both RC25 and RC35
are registered as Master.
e
Fault:
RC25-HK1 temperature sensor. The
integrated temperature sensor of the remote
control (control unit) of heating circuit 1 is
defective.
e
Fault:
RC25-HK1 communication. RC25 addressed
incorrectly, wired incorrectly or defective.
e
Fault:
RC25-HK2 temperature sensor. The
integrated temperature sensor of the remote
control (control unit) of heating circuit 2 is
defective.
LED on
Other effects
UBA 3
Reset
requi-
red?
No
Off
Both RC35 and RC25
activate heating
circuit 1 and DHW.
Depending on the
heating programs set
and the required
room temperatures,
the heating system
can no longer work
correctly. DHW
mode does not work
well.
No
Off
Since there is no
actual room
temperature
information, room
influence and
optimization of the
switch times do not
work. The EMS
works on the basis
of the values last set
on the remote
control.
No
Off
Since there is no
actual room
temperature
information, room
influence and
optimization of the
switch times do not
work.
No
Off
Since there is no
actual room
temperature
information, room
influence and
optimization of the
switch times do not
work. The EMS
works on the basis
of the values last set
on the remote
control.
6 720 648 726 (2011/07)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gb162-80Gb162-100

Table of Contents