EXCLUSIVE GREEN C.S.I. - R.S.I.
INF2 list
Step
Description
1
Input probe temperature
2
Return probe temperature
3
Sanitary probe temperature:
water tank with thermostat (A and B cases)
water tank with probe (C case)
4
Not used in this model
5
Not used in this model
6
Second heating system probe temperature
7
Not used in this model
8
Ventilator speed /100
9
Not used in this model
10
Not used in this model
11-18
Historic alarm codes
Switching off for long periods
For prolonged absences press the
The display will show two segments in the central area. Turn the main switch to
"off".
Turn off the gas tap under the boiler by turning it clockwise (Fig. 13).
In this case, the anti-freeze and anti-block systems are disabled. Empty
the water circuit or suitably protect it with a good make of anti-freeze.
Boiler functions
Filling the circuit
If circuit pressure reaches 0.6 bar, the pressure value flashes on the display
(Fig. 14); if it falls below a minimum safety value (0.3 bar), fault code 41 appears
on the display (Fig. 15) for a certain time, following which, if the fault persists,
fault code 40 is displayed (see chapter on "Troubleshooting").
In the event of faul 40 (Fig. 16) proceed as follow to restore the correct pressure
value:
- press
button
- open the filling tap external to the boiler, until the pressure shown in the
display is between 1 and 1,5 bar.
If you have to fill the system several times, contact the Technical Service Centre
to check whether the heating circuit is watertight (see if there are any leaks).
Information
Press , the display turns off and just the word InFO appears (Fig. 17). Press
the button to view operating information. Press the button again to move on to
the next piece of information. If the
automatically exits the function.
Info list:
Info 0 - shows the word InFO (Fig. 17)
Info 1 - only with the external probe connected, displays external temperature
(e.g. 12°C) (Fig. 18). The values shown on the display range between - 30°C
and 35°C. Beyond these values the display shows "- -"
Info 2 - shows circuit pressure (Fig. 19)
Info 3 - shows the set heating temperature (Fig. 20)
Info 4 - shows the setted temperature (only water tank with sensor, Fig. 21)
Info 5 - displays the set heating temperature, in reference to the second circuit,
only if it is connected.
S.A.R.A. BOOSTER function (Fig. 22)
If the "winter" mode is selected, the S.A.R.A. Booster function is activated for
the heating circuit. This function allows to reach the required ambient tempera-
ture more quickly.
Depending on the temperature set on the ambient thermostat and the time taken
to reach it, the boiler automatically adjusts the heating water temperature to
reduce operating times, thereby increasing operating comfort and energy saving.
INF2 (Fig. 23)
It is possible to display information, which may be useful for the Technical
Assistance Centre, by pressing the button
appears on the display.
16
button to switch off the boiler (Fig. 3).
button is not pressed, the system
for 10 seconds: the code "INF2"
Display
Display
2 digits
4 digits
xx
01
°C
xx
02
°C
--
03
°C
xx
03
°C
xx
Cond
°C
xx
05
xx
06
°C
xx
07
xx
FAN
xx
09
xx
10
xx
HIS0-HIS7
23