Beretta EXCLUSIVE GREEN CSI 16 User Manual page 15

Table of Contents

Advertisement

12
13
Tap closed
14
15
16
17
18
19
20
21
22
The bar segments light up (every 5°C) as the temperature is increased. The
selected temperature value appears on the display.
Adjusting heating water temperature with an external sensor
connected
When an external probe is connected, the value of the delivery temperature is
automatically chosen by the system which rapidly adjusts ambient temperature
to the changes in external temperature. Just the central segment of the bar is
illuminated (Fig. 7).
To increase or decrease the temperature with respect to the value automatically
calculated by the electronic board, turn the heating water selector clockwise to
increase and anticlockwise to decrease. The bar segments light up (at every
comfort level), correction tolerance lies between - 5 and + 5 comfort levels (Fig.
7). When choosing the level of comfort, the digit area of the display shows the
required level of comfort while the bar shows the matching segment (Fig. 8).
Adjusting domestic hot water temperature
CASE A - only heating - adjusting not applicable
CASE B - only heating + water tank with thermostat: in this condition every time
there is a request from the water tank thermostat, the boiler supplies hot water
to preparing domestic hot water. During this operation on the display the icon
flashed.
CASE C - only heating + water tank with sensor: to adjust domestic hot water
temperature storaged in the water tank, turn switch D (Fig. 9): clocwise to
increase and anticlockwise to decrease. The bar segments light up (every 3°C)
as the temperature is increased. About 4 seconds after the selection has been
made, the modification is memorised and the display returns to the delivery
temperature read by the sensor.
Working the boiler
Adjust the ambient thermostat to the required temperature (approx. 20°C). If
there is a demand for heating water, the boiler starts and the
on the display (Fig. 10). The boiler will remain working until the set temperatures
are reached, after which it will go on stand-by. In the event of ignition or operating
faults, the boiler will perform a "safety stop".
The flame symbol
will go out and the fault code and
(Fig. 11). For a description of faults and how to reset them, consult chapter
"Troubleshooting".
Switching off
Switching off for short periods
For brief absences press the
show two segments in the central area (Fig. 12). When the boiler remains
powered with the gas tap open, it is protected by the following systems:
- anti-freeze (Fig. 3): when the temperature of the water in the boiler falls below
safety values, the circulator and the burner work at minimum power to increase
the water temperature to a safe value (35°C). The
display.
- circulator anti-block: one operating cycle is performed every 24 hours.
symbol is shown
will be displayed
button to switch off the boiler. The display will
symbol lights up on the
ENGLISH
15