Adjusting heating water temperature with an external sensor
connected
When an external probe is connected, the value of the delivery temperature is
automatically chosen by the system which rapidly adjusts ambient temperature
to the changes in external temperature. Just the central segment of the bar is
illuminated (Fig. 5).
To increase or decrease the temperature with respect to the value automatically
calculated by the electronic board, turn the heating water selector clockwise to
increase and anticlockwise to decrease. The bar segments light up (at every
comfort level), correction tolerance lies between - 5 and + 5 comfort levels (Fig.
5). When choosing the level of comfort, the digit area of the display shows the
required level of comfort while the bar shows the matching segment (Fig. 6).
Adjusting domestic hot water temperature
To adjust domestic hot water temperature, turn switch B (Fig. 7) clockwise to
increase and anticlockwise to decrease. The bar segments light up (every 3°C)
as the temperature is increased.
The selected temperature value appears on the display.
When choosing the temperature, both for heating and domestic hot water, the
display shows the value being selected. About 4 seconds after the selection
has been made, the modification is memorised and the display returns to the
delivery temperature read by the probe.
Working the boiler
Adjust the ambient thermostat to the required temperature (approx. 20°C). If
there is a demand for heating water, the boiler starts and the
on the display (Fig. 8). The boiler will remain working until the set temperatures
are reached, after which it will go on stand-by. In the event of ignition or operating
faults, the boiler will perform a "safety stop".
The flame symbol
will go out and the fault code and
(Fig. 9). For a description of faults and how to reset them, consult chapter
"Troubleshooting".
Switching off
Switching off for short periods
For brief absences press the
show two segments in the central area (Fig. 3). When the boiler remains powered
with the gas tap open, it is protected by the following systems:
- anti-freeze (Fig. 10): when the temperature of the water in the boiler falls
below safety values, the circulator and the burner work at minimum power to
increase the water temperature to a safe value (35°C). The
up on the display.
- circulator anti-block: one operating cycle is performed every 24 hours.
Switching off for long periods
For prolonged absences press the
The display will show two segments in the central area. Turn the main switch to
"off".
Turn off the gas tap under the boiler by turning it clockwise (Fig. 11).
In this case, the anti-freeze and anti-block systems are disabled. Empty
the water circuit or suitably protect it with a good make of anti-freeze.
Drain the domestic hot water circuit.
Boiler functions
Semi-automatic filling
The boiler features a semi-automatic filling device which turns on by pressing
the
button when the corresponding symbol
12).
If this condition occurs it means that the system is incorrectly pressurised though
the boiler will continue to work regularly. Press the circuit filling button
start-up the filling sequence.
symbol is shown
will be displayed
button to switch off the boiler. The display will
button to switch off the boiler (Fig. 3).