Symbol Definitions - Extron electronics DXP 44 HD 4K PLUS Setup Manual

Digital matrix switchers, dxp hd 4k plus series
Hide thumbs Also See for DXP 44 HD 4K PLUS:
Table of Contents

Advertisement

Symbol definitions

]
= Carriage return and line feed
• = Space
X@
=
Input number (for ties)
X#
=
Output number
X$
=
De-embedded audio output number
X^
=
Room number (for room presets)
NOTE:
A room is a subset of operator-selected outputs that relate to each other. The DXP HD 4K PLUS switchers support up
to 10 rooms, each of which can consist of from 1 to 16 outputs.
X&
=
Global preset number
X*
=
Room preset number
NOTE:
A room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is
retrieved from memory, it becomes the current configuration.
X(
=
Video and sync mute status
X1)
=
Audio mute status
X1@
=
Audio and video mute status
X1$
=
Total inputs
X1%
=
Total outputs
X1^
=
Voltage
X1&
=
Temperature
X1*
=
Fan speed
X2!
=
Firmware version (n.nn)
X2%
=
Front panel lock mode status
(executive mode)
X3^
=
IP address or gateway address
X3&
=
Subnet mask
X4^
=
DHCP
X5#
=
Verbose mode
NOTE:
If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set
command does (for example, the read matrix name command
X5$
=
Power save mode
|
}
or
= Carriage return (no line feed)
E
or W = <Escape> key
0 through maximum number of inputs for your model (0 = untied)
0 through maximum number of outputs for your model
(Analog and S/PDIF) 1 or 2. If the audio output number entered is greater than
2, an E12 error code ("Invalid output number") is returned.
10 maximum. Each room can have up to 10 room presets (
00 – 32 (00 = current configuration)
00 – current ties for the room in view mode, 10 maximum
0 = Video and sync unmuted
1 = Video muted
2 = Video and sync muted
0 = Audio unmuted
1 = HDMI audio muted
2 = Analog audio muted
3 = HDMI and analog audio muted
0 = All audio and video unmuted
1 = Video muted (one or more outputs)
2 = Audio muted (one or more outputs)
3 = Video and audio muted (one or more outputs)
Total number of inputs for this switcher
Total number of outputs for this switcher
Positive or negative voltage and magnitude
Degrees Centigrade
In RPM
Shown to second decimal place
0 = lock mode 0: Front panel unlocked
1 = lock mode 1: Front panel locked except for enabling lock mode 2
2 = lock mode 2: Front panel locked except for making ties, saving and
recalling presets, and changing lock modes.
nnn.nnn.nnn.nnn
nnn.nnn.nnn.nnn
0 = off, 1 = on
0 = clear/none (default for Telnet connection)
1 = verbose mode (default for RS-232 and USB connections)
2 = tagged responses for queries
3 = verbose mode and tagged
E
}
CN
, returns Ipn •
0 = power save mode off (default)
1 = all functions disabled except SIS, USB, and IP communication. Can
be cancelled by pressing any front panel button.
2 = front panel buttons and all functions disabled. Can be cancelled
E
only by entering the
PSAV 0
X*
).
4 = S/PDIF audio muted
5 = HDMI and S/PDIF audio muted
6 = Analog and S/PDIF muted
7 = HDMI, analog, and S/PDIF audio
muted
X3) ]
).
}
command or by opening PCS.
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxp 84 hd 4k plusDxp 88 hd 4k plus

Table of Contents