Downloading The Software - Extron electronics DXP 44 HD 4K PLUS Setup Manual

Digital matrix switchers, dxp hd 4k plus series
Hide thumbs Also See for DXP 44 HD 4K PLUS:
Table of Contents

Advertisement

DXP HD 4K PLUS Series • Setup Guide (Continued)
Command Function
IP Setup (continued)
Configure current port timeout
Read current port timeout
Configure global IP port timeout
Read global IP port timeout
Set verbose mode
Read verbose mode
Reset
System reset to factory defaults
NOTE:
This command excludes IP settings such as IP address and subnet mask. It does not remove the file system.
Absolute system reset
NOTE:
This command includes resetting the IP address to 192.168.254.254 and the subnet mask to 255.255.0.0. The firmware
version remains the same.
NOTE: X5#
= Verbose mode
X5*
= Port timeout interval
Installing and Starting the Configuration Software
The Extron Product Configuration Software (PCS) is a Windows-based
program for the DXP HD 4K PLUS that enables you to configure the input
and output, audio, and image settings. It also lets you save and recall
presets, select EDID, and perform nearly all the other functions that can
be accomplished via the front panel controls or SIS commands.
NOTE:
EDID selection is available only through PCS. When the DXP
is connected to PCS, the power save mode is reset to 0 (power
save off).

Downloading the software

To use PCS, download the program from
it on the PC that will be connected to the
DXP, as described in the following sections.
You can also download updates to the
DXP HD 4K PLUS PCS as they become
available.
Open the Extron web page and select the
1.
Download tab.
In the in the left panel of the Download
2.
screen, click the PCS link under
Software.
On the PCS page, click the Download
3.
button in the table near the center of the
page (see
in the illustration at right).
1
On the Login page, enter the requested
4.
information. If you need an ID number,
contact your Extron representative.
14
ASCII Command
Response
(Host to Switcher)
(Switcher to Host)
E
X5*
}
0*
TC
Pti0*
E
}
X5*]
0TC
E
X5*
}
1*
TC
Pti1*
E
}
X5*]
1TC
E X5#
}
CV
Vrb
E
}
X5#]
CV
E
}
ZXXX
Zpx
E
}
ZQQQ
Zpq
0 = clear or none (default for Telnet connection)
1 = verbose mode (default for RS-232 and USB connection)
2 = tagged responses for queries
3 = verbose mode and tagged for queries
1 (10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)
www.extron.com
and install
Additional Description
X5*]
Set the current port timeout to
View the current port timeout setting.
X5*]
Set the global IP port timeout to
View the global IP port timeout setting.
Set the verbose mode and tagged
X5#]
responses to
View the current verbose mode.
]
Clear all ties and presets and reset unit
to factory default settings.
]
Clear all ties and presets and reset unit
to factory default settings.
X5*
.
X5*
.
X5#
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxp 84 hd 4k plusDxp 88 hd 4k plus