3) Room temperature control for indoor unit sensor
Depending on the installed environment, correction of the room temperature sensor may be re-
quired. Select the appropriate control setting according to the installed environment.
The temperature correction values show the difference from the Standard setting "00" (manufactur-
er's recommended value).
Function number
30
(For cooling)
(For heating)
4) Auto restart
Enables or disables automatic restart after a power interruption.
Function number
40
NOTE: Auto restart is an emergency function such as for power outage etc. Do not attempt to use
this function in normal operation. Be sure to operate the unit by remote controller or external
device.
5) Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed. Select the appropriate custom code.
Function number
44
Setting value
00
01
02
03
04
05
06
07
08
31
09
10
11
12
13
14
15
16
17
Setting value
0
0
0
1
Setting value
0
0
0
1
0
2
0
3
03-03
Setting description
Standard setting
No correction 0.0 °C
-0.5 °C
-1.0 °C
-1.5 °C
-2.0 °C
More cooling
Less heating
-2.5 °C
-3.0 °C
-3.5 °C
-4.0 °C
+0.5 °C
+1.0 °C
+1.5 °C
+2.0 °C
Less cooling
More heating
+2.5 °C
+3.0 °C
+3.5 °C
+4.0 °C
Setting description
E
n
a
b
e l
D
s i
a
b
e l
Setting description
A
B
C
D
Factory
setting
Factory setting
Factory setting

Advertisement