4-2 DISASSEMBLY PROCESS ( OUTDOOR UNIT )
Before servicing the unit, turnings of all power supplies.
Then, do not touch the electric parts for 10 minutes due to the risk of electric shock.
1. Top panel removal
1. Remove the screws ( 6 places ).
2. Front panel removal
Start from opening the Top panel.
1. Remove the screws ( 6 places ).
3. Valve cover and Switch cover removal
1. Remove the screws ( 4 places ). 2. Remove the Valve cover.
Left side view.
2. Remove the Front panel.
04-12
2. Remove the Top panel.
3. Remove the Switch cover.