6. OUTDOOR FAN CONTROL

1. Fan Speed
Zone
D-1
D-2
F
G
Refer to Fig. 10
( Fig.10 : Outside air temperature zone selection )
Outside air
temperature
21°C
12°C
2°C
* The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
* After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as table 7 without relating to the compressor frequency.
( Table 7 : Outdoor fan speed after the defrost )
1070rpm
Cooling
840/ 820/ 740/ 660/ 620/ 450
840/ 820/ 500/ 450/ 410
200/ 180
200/ 170
D
1 -
z
o
n
e
D
2 -
z
o
n
e
F zone
G zone
Dry
740/ 620/ 450
1070/ 930/ 760/ 660/ 610/ 580/ 510/ 410
200/ 180
200/ 170
Outside air
temperature
19°C
10°C
0°C
01-07
(rpm)
Heating