Fujitsu AS*G09KXCA Series Service Instruction page 81

Split type room air conditioner wall mounted type inverter
Table of Contents

Advertisement

SERVICE PARTS INFORMATION 6
Main PCB (IPM Check)
Check Point 1
Disconnect the connection wires between the Main PCB - Compressor.
Set the tester to the "Resistance" mode, and measure the resistance between the following terminals.
TM301 (P) - W400(S) / W401(R) / W402(C)
TM302 (N) -
W400(S) / W401(R) / W402(C)
*Make sure that the compresor wires are not short-circuit during the measuring.
Judge the result of
as follows:
Terminal
Tester(+)
Tester(-)
P
W400
P
W401
P
W402
W400
P
W401
P
W402
P
N
W400
N
W401
N
W402
W400
N
W401
N
W402
N
Check Point 2
Set the tester to the "Diode" mode, and measure the voltage value between the following terminals.
*Make sure that the compresor wires are not short-circuit during the measuring.
Judge the result of
as follows:
Terminal
Tester(+)
Tester(-)
W400
P
W401
P
W402
P
W400
P
W401
P
W402
P
W400
N
W401
N
W402
N
W400
N
W401
N
W402
N
Resistance value
Over 2k
(Including
)
Over 20k
(Including
)
Over 2k
(Including
)
Tester display
0.3V
0.7V
02-47