AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LUCA AS G09LUCA AS G12LUCA AS G14LUCA OUTDOOR AO G07LUC AO G12LUC AO G09LUC AO G14LUC...
FEATURE MODEL ASG07LUCA / AOG07LUC ASG09LUCA / AOG09LUC ASG12LUCA / AOG12LUC ASG14LUCA / AOG14LUC AO G07LUC AO G12LUC AO G09LUC AO G14LUC FEATURES Energy-Efficiency classification A Europe Energy-Efficiency classification A achieved Thin &...
Outdoor unit low noise *Only available with Wireless RC. When air-conditioner operates in large capacity, operation noise of outdoor unit will be suppressed. In case of room temperature being close to setting temperature, operation noise might not decrease. Down Low noise Rated noise level...
WIRELESS REMOTE CONTROLLER FEATURES 3 Mode timer setup (Weekly / Program / Sleep) are possible. Easy operation. Easy to change signal code (4 patterns) by button operation. Simple function setting Setting of the air conditioner selection function is performed by remote controller. Built-in timers ...
Page 7
FUNCTIONS Signal Transmitter MODE button FAN button 10 °C HEAT button ECONOMY button SWING button TEMP. OUTDOOR UNIT LOW button SET button NOISE button POWERFUL button TIMER SETTING button WEEKLY button START/STOP SEND button button ON/OFF button SLEEP button SELECT button RESET button NEXT button...
SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name AS G07LUCA AS G09LUCA AS G12LUCA AS G014LUCA Power source 230V~ 50Hz Available voltage range 198-264V~ 50Hz Cooling European energy label Heating 2.00 2.50 3.50 4.20 Rated BTU/h 6,800 8,500...
FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION Note: Fan speed : High MODEL : ASG07LU Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center 0.75 Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right &...
Page 15
Note: Fan speed : High MODEL : ASG09LU Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right & Left Unit : m/s SIDE VIEW Vertical flap : Up...
Page 16
Note: Fan speed : High MODEL : ASG12LU, ASG14LU Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right & Left Unit : m/s SIDE VIEW Vertical flap : Up...
7-2. AIR FLOW MODEL : ASG07LU Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1140 1050 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1180 1050 QUIET - (01 - 14) -...
Page 18
MODEL : ASG09LU Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1300 1080 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1300 1120 QUIET - (01 - 15) -...
Page 19
MODEL : ASG12LU Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1370 1120 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1370 1180 QUIET - (01 - 16) -...
Page 20
MODEL : ASG14LU Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1440 1220 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1510 1220 1030 QUIET - (01 - 17) -...
ELECTRIC CHARACTERISTICS Model name ASG07LU ASG09LU ASG12LU ASG14LU Voltage 230~ Power supply Frequency Max. operating current Connection cable 1.0-1.5 *1)Wiring Spec. Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 21) -...
SAFETY DEVICES Model ASG07LU Protection form ASG09LU ASG12LU ASG14LU Circuit protection Current fuse (PCB) 3.15A 250V Terminal protection Current (thermal) fuse 3A 250V °C OFF Fan motor protection Thermal protector program °C ON - (01 - 22) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CNA01 Control input See external CNB01 Operation status output input/output settings for details. CNB02 Error status output 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
Page 27
When function setting is "Forced stop" mode Input signal Forced stop Command Normal Operation Indoor unit Stop Remote controller Remote control operation invalidity Parts (Optional) Parts name Model name External connect kit UTY-XWZXZ5 Communication kit UTY-TWBXF * For operating the EXTERNAL function, the Compact wall mounted type requires the communication kit in addition to the wire (UTY-XWZXZ5).
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply...
Page 29
ERROR STATUS OUTPUT An air conditioner error status signal can be output. Circuit diagram example Indoor control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply * Make the distance from the PC board to the connected unit within 10m.
FUNCTION SETTING 12-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. • After the power is turned on, perform the “FUNCTION SETTING”...
FUNCTION DETAILS Compact wall Functions mounted 1) Filter sign 2) Cooler room temperature correction 3) Heater room temperature correction 4) Auto restart Indoor room temperature sensor switching function 6) Remote controller signal code 7) External input control 1) Filter sign The indoor unit has a sign to inform the user that it is time to clean the filter.
Page 32
4) Auto restart Enable or disable automatic system restart after a power outage. ( ... Factory setting) Setting description Function number Setting value * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device.
Page 33
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) Press the START/STOP ( / ) button until only the clock is displayed on the remote controller display.
OPTIONAL PARTS Exterior Parts name Model No. Summary Unit control is performed by Wired remote wired remote controller. UTY-RNNYM controller *Optional communication kit is necessary for the installation. Unit control is performed by Simple remote simple remote controller. UTY-RSNYM controller *Optional communication kit is necessary for the installation.
SPECIFICATIONS Type INVERTER COOLING & HEATING Model name AO G07LUC AO G09LUC AO G12LUC AO G14LUC Power source 230V~ 50Hz Available voltage range 198-264V ~ 50Hz Starting current Cooling 1,720 1,720 1,940 1,940 Airflow rate Heating 1,510 1,510 1,700...
DIMENSIONS MODEL : AOG07LU, AOG09LU (Unit : mm) Top view Front view Side view Air flow Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
Page 39
MODEL : AOG12LU, AOG14LU (Unit : mm) Top view Front view Side view Air flow Drain pipe 4-ø11.3mm hole mounting place (ø20) Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
ADDITIONAL CHARGE CALCULATION MODEL : AOG07LU Refrigerant type R410A Refrigerant amount Refrigerant charge Total pipe length 15 or less 20 (MAX) 20g/m Additional charge MODEL : AOG09LU Refrigerant type R410A Refrigerant amount Refrigerant charge Total pipe length 15 or less 20 (MAX)
AIR FLOW MODEL : AOG07LU Cooling Number of rotations Air flow (r.p.m.) 1720 1012 Heating Number of rotations Air flow (r.p.m.) 1510 MODEL : AOG09LU Cooling Number of rotations Air flow (r.p.m.) 1720 1012 Heating ...
Page 48
MODEL : AOG12LU Cooling Number of rotations Air flow (r.p.m.) 1940 1141 Heating Number of rotations Air flow (r.p.m.) 1700 1000 MODEL : AOG14LU Cooling Number of rotations Air flow (r.p.m.) 1940 1141 Heating ...
ELECTRIC CHARACTERISTICS Model name AO G07LU AO G09LU AO G12LU AO G14LU Voltage 230 ~ Power supply Frequency *1) Max operating current 10.5 Starting Current Main Fuse (Circuit breaker) Current *2) Wiring Spec.: Power Cable *3) Limited wiring length : *1) The maximum current is the total current of indoor unit and outdoor unit.
SAFETY DEVICES Model Protection form AO G07LU AO G09LU AO G12LU AO G14LU Current fuse 20A/250V Circuit protection (MAIN PRINTED 5A/250V CIRCUIT BOARD) Thermal protection OFF : 100 °C Fan motor protection program ON : 95 °C Terminal protection program OFF:110°C...