Summary of Contents for Fujitsu ASG07LLCC

  • Page 1: Wall Mounted Type

    AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASG07LLCC ASG09LLCC ASG12LLCC OUTDOOR AOG07LLCC AOG09LLCC AOG12LLCC...
  • Page 2: Indoor Unit

    1.INDOOR UNIT WALL MOUNTED TYPE : ASG07LLCC ASG09LLCC ASG12LLCC DTR_AS087E_02 2014.02.10...
  • Page 3: Table Of Contents

    CONTENTS 1. INDOOR UNIT 1. FEATURES ......................01 - 01 2. WIRELESS REMOTE CONTROLLER ..........01 - 03 3. SPECIFICATIONS ....................01 - 05 4. DIMENSIONS ......................01 - 07 5. WIRING DIAGRAMS ..................01 - 08 6. CAPACITY TABLE ....................
  • Page 4: Features

    FEATURES MODEL „ „ ASG07LLCC / AOG07LLCC ASG09LLCC / AOG09LLCC ASG12LLCC / AOG12LLCC FEATURES „ „ Energy effi ciency class „ MODEL AS  G07LLCC AS  G09LLCC AS  G12LLCC Cooling Heating(Average) Super quiet operation „ Fan speed Noise level Top class low noise operation by new airflow construction.
  • Page 5 Easy maintenance „ Removable & washable panel Corresponds to maximum 20m long piping „ - (01 - 02) -...
  • Page 6: Wireless Remote Controller

    WIRELESS REMOTE CONTROLLER FEATURES „ „ 3 mode timer setup available (ON/OFF/SLEEP).  „ Easy operation.  „ Easy to change custom code (max. 4 custom codes) by button  „ operation. Simple function setting „ Setting of the air conditioner selection function is performed by remote controller. Built-in timers „...
  • Page 7 FUNCTIONS „ „ Signal transmitter MODE button SET TEMP. button ( POWERFUL button ECONOMY button START/STOP button TEST RUN button This button is used when installing the air conditioner, and „ should not be used under normal conditions, as it will cause the indoor unit’s thermostat function to operate incorrectly.
  • Page 8: Specifications

    SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name AS07LLCC ASG09LLCC ASG12LLCC Power source 230V~ 50Hz Available voltage range 198 - 264V~ 50Hz 2.00 2.50 3.40 Rated Btu/h 6,800 8,500 11,600 Cooling 0.9 - 2.8 0.9 - 3.0 0.9 - 3.8 Min-Max Btu/h 3,100 - 9,500...
  • Page 9 Model name AS07LLCC ASG09LLCC ASG12LLCC Cooling Energy efficiency class Heating (Average) Cooling 2.0 (35°C) 2.5 (35°C) 3.4 (35°C) Pdesign Heating (Average) 2.2 (-10°C) 2.3 (-10°C) 3.2 (-10°C) SEER Cooling 6.70 6.90 6.60 kWh/kWh SCOP Heating (Average) 4.00 4.00 3.80 Annual energy consumption kWh/a QHE (Average) 1179...
  • Page 10: Dimensions

    DIMENSIONS MODEL : ASG07LLCC, ASG09LLCC, ASG12LLCC „ „ (Unit : mm) INSTALLATION PLACE „ „ Wall hook bracket 63 mm or more 100 mm or more 70 mm or more 1,500 mm or more 1,800 mm or more (Wall cap) - (01 - 07) -...
  • Page 11: Wiring Diagrams

    WIRING DIAGRAMS MODEL : ASG07LLCC, ASG09LLCC, ASG12LLCC „ „ - (01 - 08) -...
  • Page 12: Capacity Table

    CAPACITY TABLE 6-1. COOLING CAPACITY MODEL : ASG07LLCC „ „ 12.0 Indoor temperature °CDB °CWB °CDB 1.87 1.32 0.33 2.09 1.33 0.34 2.16 1.45 0.34 2.30 1.45 0.34 2.37 1.57 0.34 2.51 1.56 0.35 2.65 1.66 0.35 1.78 1.26 0.37 1.98 1.26 0.38...
  • Page 13: Heating Capacity

    6-2. HEATING CAPACITY MODEL : ASG07LLCC „ „ 12.3 Indoor temperature °CDB °CDB °CWB 2.42 1.22 2.36 1.24 2.30 1.27 2.24 1.30 2.19 1.32 2.51 1.17 2.45 1.20 2.39 1.22 2.33 1.24 2.27 1.27 2.75 1.15 2.68 1.18 2.61 1.20 2.55 1.23 2.48...
  • Page 14: Fan Performance And Capacity

    FAN PERFORMANCE AND CAPACITY 7-1. AIR VELOCITY DISTRIBUTION MODEL : ASG07LLCC, ASG09LLCC, ASG12LLCC „ „ Unit : m/s TOP VIEW Conditions: Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Fan speed: HIGH Operation mode: FAN Unit : m/s TOP VIEW Vertical airflow direction louver: Up Horizontal airflow direction louver: Right &...
  • Page 15: Airflow

    7-2. AIRFLOW MODEL : ASG07LLCC, ASG09LLCC, ASG12LLCC „ „ Cooling „ Number of Fan speed rotations Airflow (r.p.m) m³/h HIGH 1320 m³/h 1120 m³/h m³/h QUIET zHeating „ Number of Fan speed rotations Airflow (r.p.m) m³/h HIGH 1360 m³/h 1120 m³/h m³/h QUIET...
  • Page 16: Operation Noise (Sound Pressure)

    OPERATION NOISE (SOUND PRESSURE) 8-1. NOISE LEVEL CURVE MODEL : ASG07LLCC, ASG09LLCC „ „ Cooling Heating „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 High High NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 Quiet Quiet NC-15...
  • Page 17: Sound Level Check Point

    8-2. SOUND LEVEL CHECK POINT - (01 - 14) -...
  • Page 18: Electrical Characteristics

    ELECTRICAL CHARACTERISTICS Model name ASG07LLCC ASG09LLCC ASG12LLCC Voltage 230 ~ Power supply Frequency Max. operating current Connection cable Wiring spec. Limited wiring length Note : Wiring Spec. 1. Selected Sample (Selected based on Japan Electrotechnical Standards and Codes Committee E0005) 2.
  • Page 19: Safety Devices

    SAFETY DEVICES Model Protection form ASG07LLCC ASG09LLCC ASG12LLCC Circuit protection Current fuse (PC board) 250V 3.15A OFF: 160 ± 25 °C Fan motor protection Terminal protection program ON: 110 ± 25 °C - (01 - 16) -...
  • Page 20: Function Settings

    FUNCTION SETTINGS 11-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings may cause an indoor unit to malfunction. •...
  • Page 21: Function Details

    FUNCTION DETAILS „ „ Functions 1) Filter sign 2) Room temperature control for cooling 3) Room temperature control for heating 4) Auto restart 5) Remote controller custom code 6) Indoor unit fan control for energy saving for cooling 1) Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
  • Page 22 4) Auto restart Enable or disable automatic restart after a power interruption. (  ... Factory setting) Setting description Function number Setting value Enable  Disable * Auto restart is an emergency function such as for power outage etc. Do not attempt to use this function in normal operation.
  • Page 23 REMOTE CONTROLLER CUSTOM CODE SETTING „ „ Use the following steps to select the custom code of the remote controller. (Note that the air conditioner cannot receive a signal if the right signal code has not been set.) Press the MODE button for at least five seconds to display the current custom code (initially set to ).
  • Page 24: Optional Parts

    OPTIONAL PARTS Exterior Parts name Model No. Summary Remote Wall or pillar mountable, and controller UTZ-RXLA holds the remote controller. holder - (01 - 21) -...
  • Page 25: Outdoor Unit

    2.OUTDOOR UNIT SINGLE TYPE : AOG07LLCC AO  G09LLCC AOG12LLCC DTR_AO154E_01 2013.11.07...
  • Page 26 CONTENTS 2. OUTDOOR UNIT 1. SPECIFICATIONS ....................02 - 01 2. DIMENSIONS ......................02 - 02 3. REFRIGERANT CIRCUIT ................02 - 03 4. WIRING DIAGRAMS ..................02 - 04 5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE ..............
  • Page 27: Specifications

    SPECIFICATIONS Type INVERTER COOLING & HEATING Model name AOÛG07LLCC AOÛG09LLCC AOÛG12LLCC Power source 230 V~ 50 Hz Available voltage range 198-264 V Starting current Cooling 1,670 1,830 Air flow rate Heating 1,470 1,600 Type × Q'ty Propeller fan × 1 Motor output Cooling Sound pressure level...
  • Page 28: Dimensions

    DIMENSIONS MODELS : AOG07LLCC, AOG09LLCC, AOG12LLCC „ „ (Unit : mm) INSTALLATION PLACE „ „ CAUTION • When the outdoor temperature is 0 °C or less, do not use the accessory drain pipe and drain cap. If the drain pipe and drain cap 100 mm or more are used, the drain water in the pipe may 100 mm or more...
  • Page 29: Refrigerant Circuit

    REFRIGERANT CIRCUIT MODELS : AOG07LLCC, AOG09LLCC, AOG12LLCC „ „ : Cooling : Heating Refrigerant pipe diameter Liquid: 1/4" (6.35mm) Gas: 3/8" (9.52 mm) - (02 - 03) -...
  • Page 30: Wiring Diagrams

    WIRING DIAGRAMS MODEL : AOG07LLCC, AOG09LLCC, AOG12LLCC „ „ - (02 - 04) -...
  • Page 31: Capacity Compensation Rate For Pipe Length

    CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE MODEL: AO G07LLCC, AOG09LLCC „ „ Pipe length (m) COOLING 0.872 0.910 Û 1 0.961 0.886 0.925 Indoor unit is higher 0.979 0.965 0.890 0.929 than outdoor unit. 0.992 0.983 0.969 0.893 0.933 Height difference H...
  • Page 32 MODEL : AOG12LLCC „ „ Pipe length (m) COOLING 0.858 0.868 Û 1 0.929 0.872 0.882 Indoor unit is higher 0.960 0.933 0.876 0.885 than outdoor unit. 0.992 0.964 0.937 0.879 0.889 Height difference H 1.000 0.972 0.944 0.887 0.896 1.000 0.972 0.944...
  • Page 33: Refrigerant Charge

    ADDITIONAL CHARGE CALCULATION MODELS : AOG07LLCC, AOG09LLCC „ „ Refrigerant type R410A Refrigerant amount Refrigerant charge „ Total pipe length 15 or less 20 (Max.) 20g/m Additional charge MODEL : AOG12LLCC „ „ Refrigerant type R410A Refrigerant amount Refrigerant charge „...
  • Page 34: Airflow

    AIRFLOW MODELS : AOG07LLCC, AOG09LLCC „ „ Cooling „ Number of rotations Airflow (r.p.m.) 1670 Heating „ Number of rotations Airflow (r.p.m.) 1470 MODEL : AOG12LLCC „ „ Cooling „ Number of rotations Airflow (r.p.m.) 1830 1078 Heating „ Number of rotations Airflow (r.p.m.)
  • Page 35: Operation Noise (Sound Pressure)

    OPERATION NOISE (SOUND PRESSURE) 8-1. NOISE LEVEL CURVE MODEL : AOG07LLCC „ „ Cooling Heating „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000...
  • Page 36 MODEL : AOG12LLCC „ „ Cooling Heating „ „ NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency,Hz Octave band center frequency,Hz - (02 - 10) -...
  • Page 37: Sound Level Check Point

    8-2. SOUND LEVEL CHECK POINT Airflow - (02 - 11) -...
  • Page 38: Electrical Characteristics

    ELECTRICAL CHARACTERISTICS Model name AOÛG07LLCC AOÛG09LLCC AOÛG12LLCC Voltage 230 ~ Power supply Frequency Max. operating current *1 Starting current Circuit breaker current Wiring spec. *2 Power cable *1: The maximum current is the total current of indoor unit and outdoor unit. *2: Wiring spec.: Selected sample (Selected based on Japan Electrotechnical Standards and Codes Committee E0005)
  • Page 39: Safety Devices

    SAFETY DEVICES Model AOÛG07LLCC Protection form AOÛG09LLCC AOÛG12LLCC 250V 25A Current fuse Circuit protection (Main printed circuit board) 250V 5A OFF: 100 ± 15 °C Fan motor protection Terminal protection program ON: 95 ± 10 °C Terminal protection program OFF: 110°C Compressor protection (Discharge temp.) ON: After 7 minutes...