Fujitsu AS*G09KXCA Series Service Instruction page 104

Split type room air conditioner wall mounted type inverter
Table of Contents

Advertisement

Before servicing the unit, turnings of all power supplies.
Then, do not touch the electric parts for 10 minutes due to the risk of electric shock.
5. Fan motor removal
Start from opening the Front panel.
1. Remove the Electric box cover and release cables from cable guide.
2. Disconnect the connector. ( P650 / White )
3. Cut the binder with Fan motor wire and Solenoid coil wire.
4. Remove the Hex socket screw.
6. Side panel removal
Start from opening the Front panel and Valve and switch cover.
1. Remove the screws ( 9 places ).
5. Remove the Propeller Fan.
6. Remove the screws ( 4 places ).
Hooks ( 2 places )
2. Remove the Side panel.
04-14
Note at the installation.
Insert Propeller Fan and
Motor Shaft reference
D cutting position and
Tightening torque is
from 10 to 15N-m.