Chapter 8
Maintenance

Manual preventive maintenance

The system requires no preventive maintenance except
cleaning with a dry, soft cloth.
Warning! Do not use any detergents to clean
the Climate Control Zoning System II.

Automatic preventive maintenance

The system is equipped with an automatic exercise function
that consists of a test run designed to prevent the pump and
actuators from seizing up due to inactivity.
This exercise is run every six days ±24 hours at random.
• The pump exercise operates only if the pump has not been
activated since the last exercise. The pump is activated for
3 minutes during the exercise.
• The actuator exercise operates only if the actuators have not
been activated since the last exercise. The exercise consists
of opening and completely closing the actuators periodically.

Corrective maintenance

Fallback mode

If a thermostat is malfunctioning or not detected, the controller
executes the fallback mode to maintain the temperature in the
room until the problem is resolved.

Resetting the controller

If the controller does not work as expected, for example
due to a hang-up, it can be reset to solve the problem.
1. Disconnect and reconnect the controller to AC power.

Controller LEDs

Uponor recommends occasionally checking the power
LED on the controller for alarms. The power LED flashes
continuously for general alarms. Determine which thermostats
are issuing alarms by removing the cover. If a channel
LED is indicating an error, check the function and batteries
of the registered thermostat.
The controller power LED is on during normal operation.
All the channel LEDs are off when there is no current or
waiting actuator activity. The LEDs turn on when the
corresponding actuators are activated or start flashing
when they are awaiting activation.
Up to eight actuators in six rooms can be in the opening process
at the same time. If a slave module is installed, the LEDs of the
seventh and subsequent actuators flash while they are waiting
for the previous actuators to be fully open.
Climate Control Zoning System II installation and operation manual | Chapter 8 – Maintenance l 29
The illustration below shows the position of the controller LEDs.
B
Figure 8-1: Controller LEDs
Item
Description
A
Power LED
B
Channel LEDs
The table below describes the status of the base unit LEDs.
LED
Status
Power
The base unit power LED is always on and flashes
when a problem occurs, such as:
• Loss of radio transmission from a thermostat
for more than 1 hour
• Loss of radio transmission from a timer or an
interface for more than 15 minutes
Channel during
• Red, on – actuators activated
run mode
• Red, flashing – thermostat communication
error or low battery indication
• Off – no demand for heating or cooling
Channel during
• Red, on – thermostat registered but with
registering
communication errors
mode
• Green, on – thermostat registered and
communication is OK
• Red, flashing – selector pointing at channel
• Green, flashing – channel selected to
be registered
• Off – channel not pointed, nor registered
Channel during
• Red, on – actuators activated
forced mode
• Red, flashing – selector pointing at channel
• Off – channel not pointed, nor activated