Jamie
March 15, 2025

How do I switch from Celsius to Fahrenheit on my thermostat heat only

1 comments:
Mr. Anderson
March 15, 2025

To switch from Celsius to Fahrenheit on the Uponor Heat-only Thermostat:

1. Ensure the thermostat is turned on and in HEAT mode.
2. Make sure the SET indicator is not flashing.
3. Ensure the rectangle is around the AIR button.
4. If no rectangle is present, press the AIR button once.

This will change the temperature units from Celsius to Fahrenheit.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Uponor Heat-only Thermostat

  • Page 1 Uponor Heat-only Thermostat with Touchscreen Installation and operation manual...
  • Page 2: Getting Started

    Overview Installation overview The Uponor Heat-only Thermostat (A3100101) is designed Prior to installing the Uponor thermostat, follow the instructions for precise temperature control of hydronic radiant heating below. (Note: Only experienced and trained professionals familiar applications. The thermostat includes an option to add a floor with low-voltage wiring should attempt to install the thermostat.)
  • Page 3: Sequence Of Operation

    (PWM) control functions to ensure pins are correctly aligned with the terminals. Do not apply zone is comfortable and energy efficient. extreme pressure to the display area as damage to the equipment may result. Uponor Heat-only Thermostat with Touchscreen l 3...
  • Page 4: Thermostat Display

    Heating modes Note: In PWM mode, the heating equipment may temporarily turn off even when the heating indicator is flashing (showing a This thermostat can operate a hydronic radiant system call for heat). heating operation based on the air sensor measure operative temperature, a floor sensor, or a combination of both to provide Freeze protection the optimal level of comfort and control.
  • Page 5: Advanced Settings

    • Confirm this action by checking that the SET indicator appears and flashes with the horizontal bar. Advanced settings This Uponor thermostat features advanced settings which can help better manage the system. These settings should only be accessed and changed by a qualified installer. Improper adjustment of these settings can result in incorrect operation of the heating system.
  • Page 6: Error Codes

    Setting the maximum floor protection limit • When the thermostat is set up for floor sensor operation (no air) and the floor sensor fails, ERROR will appear on Depending on the installation or application, it the display. The thermostat will ignore any slab setpoint may be necessary to limit how warm the floor gets temperature.
  • Page 7 Figure 4: Uponor thermostat wired to a boiler (Optional) (Optional) (Optional) (Optional) Party Party A3011075 Zone Valve A3011075 Zone Valve Boiler Boiler Figure 3: Uponor thermostat wired to an actuator or zone valve A3011075 Zone Valve A3011075 Zone Valve Uponor Heat-only Thermostat with Touchscreen l 7...
  • Page 8: Technical Specifications

    5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Apple Valley, MN 55124 Mississauga, ON L5N 1W1 CANADA T 800.321.4739 T 888.994.7726 F 952.891.2008 F 800.638.9517 uponorpro.com A3100101_heat-onlyTstatWtouchscreen_manual_0316, Copyright © 2016 Uponor. Printed in the United States. MKT10050-AA...