• Do not use water to clean electrical Uponor products/ components. Uponor is not liable for damage caused by ignoring the instructions in this document or the applicable building code. Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual...
Uponor website: www.uponor.com. CD0000776 The Uponor Smatrix Base thermostat D+RH T-247 BUS comes with a big LED display and capacitive keys. The capacitive keys and the front glass make cleaning of the front of the thermostat easy.
Relative humidity measured with seconds timeout period, the thermostat will display the "not paired" the RH sensor icon ( ). After a few seconds, it will return to run mode, displaying the main screen. Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual...
When you press the OK button, the display switches from the main screen to the humidity measurement screen. • After 10 seconds of inactivity, the display will automatically return to the main screen. Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual...
4.6 Digital thermostat functions Run mode The thermostat is in run mode during normal operation. The display turns off after 20 seconds of inactivity and can only be reactivated by pressing a button. Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual...
Page 9
Heating/cooling changeover If the setback temperature is set to 0, the thermostat will remain This menu is not visible if the thermostat is registered to a Uponor unaffected if a program sets the system in ECO mode. Smatrix Base Pulse controller.
This menu is only visible if control mode RFT is activated in settings menu 04. For systems with a communication module, this menu only shows the set value Changes can be made in the Uponor Smatrix Pulse app. See Change the settings, Page 9 , for how to change the setting.
This section describes general problems and alarms that can occur with the Uponor Smatrix system and gives solutions for them. Problems are frequently caused by loops that are installed incorrectly or by thermostats that are in the incorrect room or that are registered The display remains inactive after incorrectly.
Defective temperature sensor Note – Make sure that the remote sensor is connected correctly. Relative humidity control is activated in the Uponor – Disconnect the remote temperature sensor and examine it Smatrix Pulse app (requires communication module). with an ohmmeter. Make sure that the value agrees with the •...
If the loop becomes warm, the cause can be the room control system. A supply system malfunction can be identified by no warm water in the manifold. Do a check of the boiler and circulation pump. Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual...
The full text of the EU/UK declaration of conformity is available at the following internet address: https://www.uponor.com/doc/1071651 1) Refer to the related Uponor product for the specified certification and compliance marks. Additional product information and instructions are delivered with the Uponor product.
Page 15
Uponor GmbH Industriestraße 56, D-97437 Hassfurt, Germany Uponor reserves the right to change the product portfolio and the 1145510 v1_01_2025_EN related documentation without prior notification, in line with its policy of www.uponor.com Production: Uponor / SKA continuous improvement and development.