Uponor A3800165 Instruction Sheet
Uponor A3800165 Instruction Sheet

Uponor A3800165 Instruction Sheet

Climate control zoning system ii
Hide thumbs Also See for A3800165:

Advertisement

Climate Control Zoning System II
instruction sheet
A3800165
A3801160
A3801165
A3800167

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A3800165 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Uponor A3800165

  • Page 1 Climate Control Zoning System II instruction sheet A3800165 A3801160 A3801165 A3800167...
  • Page 2: Table Of Contents

    System example ........4 Foreword Uponor has prepared this document and all the content While Uponor has made efforts to ensure the document is included solely for information purposes. The contents of this accurate, Uponor does not guarantee or warrant the accuracy document (including graphics, logos, icons, text, and images) of the information contained herein.
  • Page 3: Overview

    • Switch off all power supply before starting any wiring work. radio frequency energy and, if not installed and used in • Do not use water to clean Uponor components. accordance with the instructions, may cause harmful interference • Do not expose Uponor components to flammable to radio communications.
  • Page 4: Installation

    Installation System components Part no . Description A3800165 Wireless Dial Thermostat (T-165) A3800167 Wireless Digital Thermostat (T-167) A3801165 Wireless Base Unit, 6 zones (X-165) A3801160 Wireless Base Unit Expansion Module, 6 zones (M-160) System example 4 | uponorpro.com...
  • Page 5: Wiring Diagram

    Wiring diagram Important! This instruction sheet serves as a reminder for experienced installers. Uponor strongly recommends using the full installation and operation manual for complete installation details. Pump relay Boiler/heat source 15.75" > (40 cm) 24 VAC Thermostat operating instructions...
  • Page 6 A3801165 A3800167 A3800167 A3801160 A3800165 A3801165 A3801165 A3801160 1 2 3 4 A3800167 A3800167 A3801165 6 | uponorpro.com...
  • Page 7: System Setup

    System setup Important! Connect only one actuator for each channel. Channels 01 and 02 have double outputs (a and b) for two actuators. Caution! Ensure that each actuator is connected to the correct channel so that the thermostats are controlling the correct loops.
  • Page 8 A3800165 A3800167 8 | uponorpro.com...
  • Page 9: Register Thermostat And/Or System Device To A Controller

    Repeat steps 2a and 2b until all channels to be registered with the thermostat are selected (LEDs flashing green). Unregister all channels Note: Uponor recommends registerating all channels to the When one or more channels (thermostats) are inaccurately thermostat at the same time.
  • Page 10: Technical Data

    Technical data General IP20 (IP: degree of inaccessibility to active parts of the product and degree of water) Maximum ambient RH (relative humidity) 85% at 68°F (20°C) Antenna Power supply From controller Radio frequency 912 MHz Transmitter duty cycle <1% Receiver class Thermostats Low-voltage tests...
  • Page 11 Climate Control Zoning System II instruction sheet l 11...
  • Page 12 5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Apple Valley, MN 55124 Mississauga, ON L5N 1W1 CANADA T 800.321.4739 T 888.994.7726 F 952.891.2008 F 800.638.9517 uponorpro .com CCZII_InstructionSheet_69569_1216, Copyright © 2016 Uponor. Printed in the United States. MKT10059_AB...