If the "for the duration tunnel" is established, the user is not shown anything when the connection
is made; however, anything sent by the user, such as from HyperTerm, will be sent out the serial
interface of the remote WAG. This is because once the tunnel is established, the WAG, which the
user used to request the connection, will immediately be placed into Data Mode.
If the "for the duration tunnel" can not be established for any of the following reasons, the user is
not shown anything either.
The remote WAG is not powered up.
The remote WAG is not connected to the LAN.
The remote WAG is not configured for the same Serial Telnet number.
The remote WAG is not configured for RAW.
The remote WAG is not in Data Mode.
Since the connection is not established, the WAG will remain in Command Mode.
3.7

CHANGING THE DIAGNOSTIC VERBOSITY LEVELS

The WAG sends run-time messages out the serial interface when the serial interface is in
Command Mode. Each run-time message is assigned a verbosity level at which it is displayed. The
allowable verbosity levels are 0 through 65534, however only 1 through 10 are significant.
1
-
No logging of diagnostic information.
10 -
Enables the logging of diagnostic information regarding multipart ATCS messages.
To Change the Verbosity Levels:
1. Type verbosity and press Enter. The current verbosity information appears.
2. To change the level, type verbosity nn and press Enter, where nn is a number from 1 to
10.
3.8

SEND WINK REQUEST TO A WAG

This command is used to allow the user to visually confirm which WAG the user is talking to.
When the user enters the winkwag command followed by an ATCS address, the WAG will send a
wink command to that particular WAG causing the Health LED to flash quickly for a period of
time. And if the user types wink followed by a Type 7 ATCS address, the WAG with that type 7
address on the broadcast medium will wink.
To Use the Winkwag Command:
Type wink and press Enter. The Health LED on the particular WAG flashes rapidly.