Figure 2-46. Change Routing Region Domain One - Ip Address Screen; Figure 2-47. Change Routing Region Domain One - Symbolic Name Screen - Siemens A53457 Installation & Maintenance

Wayside access gateway wag
Table of Contents

Advertisement

Figure 2-46. Change Routing Region Domain One - IP Address Screen

4.
On the Symbolic Name screen (figure 2-47), enter the symbolic name for Routing Region
Domain 1. Entries can consist of up to 40 characters including A-Z, 1-9 and 0, periods (.) and
dashes (-). After entering the symbolic name, press ENTER.
The user will be returned to the Second Configuration Menu.
Figure 2-47. Change Routing Region Domain One – Symbolic Name Screen
5.
Prior to exiting the First Configuration Menu, select "Save changes then restart" to save
changes and restart the WAG.
2.6.19
Routing Region Domain 2
Routing Region Domain 2 is identical to Routing Region Domain 1 described in paragraph 2.6.18
above. If this function is configured with a valid IP address, copies of every "route request"
message the WAG sends will be transmitted out this IP address as well as Domain 1.
Two "domains" are provided in the event a router is located somewhere on the LAN that provides
redundant paths from the WAG to the office equipment.
If a DNS server is configured into the WAG, symbolic names for the Domain may be provided and
the WAG will look up the IP address for the symbolic name.
This function defaults to Disabled.
Refer to paragraph 2.6.18 for instructions on how to set Routing Region Domain 2. The Routing
Region Domain 2 option is on the Second Configuration Menu.
Document No.: COM-00-05-16
Version: C.1
INSTALLATION AND CONFIGURATION
2-35
June 2006, Revised June 2014