[Co-Extension Path Test] - Panasonic KX-TD500 Installation Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD500:
Table of Contents

Advertisement

5.2.1
Card/Port Test (On-line diagnosis)

[CO-Extension Path Test]

This test is executed by selecting a trunk card in "Card Information" screen.
A trunk port and an extension port are tested in pairs.
6. Click CO-Extension Path Test .
• "CO-Extension Path Test" screen is displayed.
7. Specify a port number of the CO card to be tested.
8. Specify an Extension Card and its port number to be tested.
9. Click Execute .
• After executing the test, the test result is displayed.
Example: When an LCOT card is installed in the Slot No. 104 and a DHLC card
Description
CO Card
Port No.
Extension Card
Port No.
Result
Error Indication
is installed in the Slot No.103.
Item
Display/Input Value
Card No. : Type
1-8/ all
Card No. : Type
1-8/16/all
OK
NG
See "Error Indication
Table."
Description
The card number and the type of the target card
to be diagnosed. (The card specified in "Card
Information" screen is displayed automatically.)
Used to specify the port number of the trunk
card to be diagnosed.
Used to specify the pair extension card (in OUS
status) to be diagnosed.
Options:SLC/HLC/SLC-M/ESLC/DHLC
Used to specify the port number of the
extension card to be diagnosed.
The results of diagnosis.
The details of an error.
Displayed only when Result is NG (no good).
TXXXXX&EXXXXX:"Error Message"
(XXXXX:Physical port no. CO & Extension)
Utility
5-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents