4.1.1 Slot Assignment
Value Range
Parameter
(default)
Bell
1 - 15 sec
Disappearance
Timer
Pulse Type
1. Type-A: Normal
2. Type-B: New
3. Type-C: Sweden
(Type-A)
DTMF Inter
64 - 304 msec
Digit Pause
in 16 msec
Time
increments
(112)
Bell Detection
24 - 1200 msec
Time
in 24 msec
increments
(144)
Flash Time
16 - 4080 msec
in 16 msec
increments
(80)
Gain
-3dB - +3dB
Adjustment
in 0.5 increments
Pulse Break
-16 - +16 msec
Time
Adjustment
Caller ID
1. Yes
Detection
2. No
(Yes)
4-8
System Programming
Specifies the length of time in seconds the system
(5)
requires to confirm the disappearance of the bell signal
from local Central Office.
Dial Pulse Signal type is fixed to "Type-A: Normal."
Zealand
Specifies DTMF Inter Digit Pause Time.
Specifies the length of time in milliseconds the system
requires to determine that the received signal is the bell
signal.
Specifies the length of Flash signal which the system
sends to the local Central Office.
[Note]
• This setting is valid when Group-Trunk Group
"Hooking Time"(See Section 4.3.1) is set to "80 ms."
• This setting is required when Hooking Time required
by the local Central Office is not listed in Trunk
Group "Hooking Time" assignment.
Used to adjust the volume level of the call.
(0)
Specifies the pulse break time for pulse digits.
(0)
Activates or deactivates the detection of caller ID
signals transmitted from the Central Office.
Description/Function