System Timer 2/2 - Panasonic KX-TD500 Installation Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD500:
Table of Contents

Advertisement

4.2.4 System Timer

4.2.4.2 System Timer 2/2

Value Range
Parameter
(default)
Timed Reminder
30 - 240 sec
Ringing Time
Call Parking
0 - 1,800 sec
Recall Time
TIE Inter Digit
3 - 30 sec
Time
DISA Prolong
0 - 7 min
Time
Specifies the length of time in seconds the Timed
(30)
Reminder alarm rings.
Specifies the length of time in seconds the system is to
(60)
wait before alerting (Call Parking Recall) the extension
who parked the call.
Specifies the maximum time allowed between digits on
(5)
a TIE call after it was received by the system.
Specifies the maximum time allowed to the DISA
(3)
caller for prolonging the call duration of a CO-to-CO
line call via DISA.
[Note]
A CO-to-CO line call duration is initially limited by
"CO-to-CO Line Call Duration Time."
However, the DISA caller can prolong the call
duration after hearing the warning tone by pressing
any key (except the " " key). This parameter
specifies the duration of these extended period.
Description/Function
System Programming
Reference
(U/M) p.
(U/M) p.
Tie Lines
(F/G)
DISA
(F/G)
4-37