4.3.2 Extension Group

Used to assign various parameters for up to 128 (1-128) Extension Groups.
Value Range
Parameter
(default)
Group No.
(1), (128)
FDN
3 - 4 digits
consisting of 0-9
Group Type
1. None
2. Terminate
3. Circular
4. Ring
5. Operator
6. VM
7. AA
8. UCD
(Group
no.128:Operator)
(Others:None)
1-128
Specifies the Extension Group number which you are
going to program.
Specifies the FDN (Floating Directory Number) for
the Extension Group.
(Blank)
Specifies the Group Type for each Extension Group.
This determines how the Extension Group handles the
incoming calls directed to it.
1. None:
2. Terminate: Functions as a Station Hunting Group
3. Circular:
4. Ring:
5. Operator:
6. VM:
7. AA:
8. UCD:
Description/Function
No Group Type is specified.
(Terminate).
Functions as a Station Hunting Group
(Circular).
Functions as a Ring Group.
Functions as an Operator Group.
Functions as a VM (Voice Mail) Group.
Functions as an AA (Automated
Attendant) Group.
Functions as a UCD (Uniform Call
Distribution) Group.
System Programming
Reference
None
Extension
Group
(F/G)
4-53

Hide quick links: