Panasonic KX-TD500 Installation Manual page 115

Digital super hybrid system
Hide thumbs Also See for KX-TD500:
Table of Contents

Advertisement

2.11
Lightning Protectors
Installation of an Earth Rod
Lightning
Protector
CO
Grounding
Wire
(Underground)
1)
Installation location of the earth rod...................Near the protector
2) Check obstructions ...............................................None
3) Composition of the earth rod ...............................Metal
4) Depth of the earth rod ..........................................More than 50 cm
5) Size of the grounding wire...................................Thickness is more
[Notes]
• The above figures are recommendations only.
• The length of earth rod and the required depth depend on the composition of
the soil.
Main
Unit
Earth Rod
(20 inches)
than 16 AWG
Installation
2-79

Hide quick links: