VFC 3610 / VFC 5610
E1: Input terminal parameters
Code
E1.00
X1 input
...
...
E1.03
X4 input
E1.04 X5 input
E1.15 2-wire / 3-wire running control
E1.16 Up / Down terminal change rate
E1.17 Up / Down terminal initial frequency
E1.25 Pulse input maximum frequency
E1.26 Pulse input filter time
E1.35 AI1 input mode
E1.40 AI2 input mode
E1.38 AI1 gain
E1.43 AI2 gain
E1.60 Motor temperature sensor channel
E1.61 Broken wire reaction mode
E1.68 Analog setting curve selection
E1.69 Analog channel filter time
E1.70 Input curve 1 minimum
E1.71 Input curve 1 minimum value
E1.72 Input curve 1 maximum
E1.73 Input curve 1 maximum value
E1.75 Input curve 2 minimum
E1.76 Input curve 2 minimum value
E1.77 Input curve 2 maximum
E1.78 Input curve 2 maximum value
Setting range of E1.00...E1.03 (0...41), E1.04 (0...47):
0: No function assigned
DOK-RCON04-VFC-X610***-QU06-EN-P
Name
0...41
0...47
0...4
0.10...100.00 Hz/s
0.00...[E0.09] Hz
0.0...50.0 kHz
0.000...2.000 s
0: 0...20 mA
1: 4...20 mA
2: 0...10 V
3: 0...5 V
4: 2...10 V
0.00...10.00
0.00...10.00
0: Disabled
1: AI1 analog input
2: AI2 analog input
0: Inactive
1: Warning
2: Error
0...7
0.000...2.000 s
0.0 %...[E1.72]
0.00...[E0.09] Hz
[E1.70]...100.0 %
0.00...[E0.09] Hz
0.0 %...[E1.77]
0.00...[E0.09] Hz
[E1.75]...100.0 %
0.00...[E0.09] Hz
Setting range
Default
1.00
0.00
50.0
0.100
1.00
1.00
0.100
0.0
0.00
100.0
50.00
0.0
0.00
100.0
50.00
Bosch Rexroth AG
Start-up
Min.
Attri.
0
–
Stop
0
–
Stop
0
–
Stop
0.01
Run
0.01
Run
0.1
Run
0.001
Run
2
–
Run
1
–
Run
0.01
Run
0.01
Run
0
–
Stop
0
–
Stop
0
–
Run
0.001
Run
0.1
Run
0.01
Run
0.1
Run
0.01
Run
0.1
Run
0.01
Run
0.1
Run
0.01
Run
33/51