C2: V/F Control Parameters - REXROTH VFC 5610 Quick Start Manual

Frequency converter
Hide thumbs Also See for VFC 5610:
Table of Contents

Advertisement

Bosch Rexroth AG
Start-up

C2: V/f control parameters

Code
Name
C2.00 V/f curve mode
C2.01 V/f frequency 1
C2.02 V/f voltage 1
C2.03 V/f frequency 2
C2.04 V/f voltage 2
C2.05 V/f frequency 3
C2.06 V/f voltage 3
C2.07 Slip compensation factor
C2.21 Torque boost mode
C2.22 Torque boost factor
Heavy load stabilization
C2.23
setting
Light load oscillation damping
C2.24
factor
Light load oscillation damping
C2.25
filter factor
C2.40 Current limitation mode
C2.42 Current limitation level
Current limitation
C2.43
proportional factor
Current limitation
C2.44
integral time
28/51
Setting range
0: Linear mode
1: Square curve
2: User-defined curve
0.00...[C2.03] Hz
0.0...120.0 %
[C2.01]...[C2.05] Hz
0.0...120.0 %
[C2.03]...[E0.08] Hz
0.0...120.0 %
0...200 %
0.0 %: Automatic boost
0.1...20.0 %: Manual boost
0...320 %
0: Inactive
1: Active
0...5,000 %
10...2,000 %
0: Always inactive
1: Inactive at constant speed
2: Active at constant speed
[C0.27]...250 %
0.000...10.000
0.001...10.000
VFC 3610 / VFC 5610
Default
Min.
0
0.00
0.01
0.0
0.1
0.00
0.01
0.0
0.1
0.00
0.01
0.0
0.1
0
1
0.0
0.1
50
1
1
0
1
100
1
0
200
1
DOM
0.001
DOM
0.001
DOK-RCON04-VFC-X610***-QU06-EN-P
Attri.
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Run
Run
Run
Run
Run
Run
Stop
Stop
Stop
Stop

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vfc 3610

Table of Contents