Cable Specifications; Power Connection; Cable Specification For International Without Usa / Canada - REXROTH VFC 5610 Quick Start Manual

Frequency converter
Hide thumbs Also See for VFC 5610:
Table of Contents

Advertisement

VFC 3610 / VFC 5610

2.2 Cable Specifications

2.2.1 Power Connection

Cable specification for international without USA / Canada

ONLY USE copper wires of 90 ℃ or above with XLPE or EPR insu-
lation according to IEC60364-5-52.
It is recommended to use shielded cables to connect the motor.
Model 3K00: ONLY available with VFC 3610.
*: If additional labels available with the terminals of 0K40...7K50,
please refer to the torque data on labels.
VFC x610
Fuse (gG)
Model
[A]
0K40
10.0
0K75
16.0
1K50
25.0
2K20
32.0
Tab. 2-1: 1P 200 VAC fuse and cable dimensions for international without USA / Canada
VFC x610
Fuse (gG)
Model
[A]
0K40
6.0
0K75
10.0
1K50
10.0
2K20
16.0
3K00
20.0
4K00
20.0
5K50
32.0
7K50
40.0
11K0
50.0
15K0
63.0
18K5
80.0
Tab. 2-2: 3P 400 VAC fuse and cable dimensions for international without USA / Canada
DOK-RCON04-VFC-X610***-QU06-EN-P
Power cables installation mode
B1
B2
[mm
2
]
[mm
2
]
2.5
2.5
2.5
2.5
4.0
4.0
6.0
6.0
Power cables installation mode
B1
B2
[mm
2
]
[mm
2
]
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
6.0
6.0
10.0
10.0
10.0
10.0
10.0
25.0
25.0
Bosch Rexroth AG
Electric Installation
PE Cable
E
[mm
2
]
[mm
2
]
2.5
10.0
2.5
10.0
2.5
10.0
4.0
10.0
PE Cable
E
[mm
2
]
[mm
2
]
2.5
10.0
2.5
10.0
2.5
10.0
2.5
10.0
2.5
10.0
2.5
10.0
4.0
10.0
6.0
10.0
10.0
10.0
10.0
10.0
16.0
16.0
Torque / Screw
[N·m / lb·in] (Mx)
1.00* / 9.0 (M3)
1.00* / 9.0 (M3)
1.00* / 9.0 (M3)
1.00* / 9.0 (M3)
Torque / Screw
[N·m / lb·in] (Mx)
1.00* / 9.0 (M3)
1.00* / 9.0 (M3)
1.00* / 9.0 (M3)
1.00* / 9.0 (M3)
1.00* / 9.0 (M3)
1.00* / 9.0 (M3)
1.20* / 10.5 (M4)
1.20* / 10.5 (M4)
1.76 / 15.6 (M4)
1.76 / 15.6 (M4)
3.73 / 33.0 (M5)